David C Sloas1, Scott A Stewart1, Richard S Sweat1
11 Department of Biomedical Engineering, Tulane University , New Orleans, Louisiana.
Background:
Lymphatic function is critical for maintaining interstitial fluid balance and is linked to multiple pathological conditions. While smooth muscle contractile mechanisms responsible for fluid flow through collecting lymphatic vessels are well studied, how fluid flows into and through initial lymphatic networks remains poorly understood. The objective of this study was to estimate the pressure difference needed for flow through an intact initial lymphatic network.
Methods And Results:
Pressure drops were computed for real and theoretical networks with varying branch orders using a segmental Poiseuille flow model. Vessel geometries per branch order were based on measurements from adult Wistar rat mesenteric initial lymphatic networks. For computational predications based on real network geometries and combinations of low or high output velocities (2 mm/s, 4 mm/s) and viscosities (1 cp, 1.5 cp), pressure drops were estimated to range 0.31-2.57 mmHg. The anatomical data for the real networks were also used to create a set of theoretical networks in order to identify possible minimum and maximum pressure drops. The pressure difference range for the theoretical networks was 0.16-3.16 mmHg.
Conclusions:
The results support the possibility for suction pressures generated from cyclic smooth muscle contractions of upstream collecting lymphatics being sufficient for fluid flow through an initial lymphatic network.
Related Concept Videos
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Bernoulli's Equation: Problem Solving
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity equation is...
Applications of Integration to Find Blood Flow
Design Example: Designing a Residential Plumbing System
Design Example: Flow of Oil Through Circular Pipes
Laminar Flow