Abstract:
This study compares the shutter-speed (SS) and the Tofts models as used in assessing therapeutic response in a longitudinal DCE-MRI experiment. Sixteen nu/nu mice with implanted colorectal adenocarcinoma cell line (LS-174T) were randomly assigned into treatment/control groups (n = 8/group) and received bevacizumab/saline twice weekly (Day1/Day4/Day8). All mice were scanned at one pre- (Day0) and two post-treatment (Day2/Day9) time points using a high spatiotemporal resolution DCE-MRI pulse sequence. The CA extravasation rate constant [Formula: see text] from the Tofts/SS model and the mean intracellular water residence time [Formula: see text] from the SS model were analyzed. A biological subvolume (BV) within the tumor was identified based on the [Formula: see text] intensity distribution, and the SS model parameters within the BV ([Formula: see text] and [Formula: see text]) were analyzed. It is found that [Formula: see text] and [Formula: see text] have a similar spatial distribution in the tumor volume. The Bayesian information criterion results show that the SS model was a better fit for all scans. At Day9, the treatment group had significantly higher tumor mean [Formula: see text] (p = 0.021), [Formula: see text] (p = 0.021) and [Formula: see text] (p = 0.045). When BV from transcytolemmal water exchange analysis was adopted, the treatment group had higher mean [Formula: see text] at both Day2 (p = 0.038) and Day9 (p = 0.007). Additionally, at Day9, the treatment group had higher mean [Formula: see text] (p = 0.045) and higher [Formula: see text] spatial heterogeneity indices (Rényi dimensions) d 1 (p = 0.010) and d 2 (p = 0.021). When mean [Formula: see text] and its coefficient of variation (CV) were used to separate treatment/control group samples using supporting vector machine, the accuracy of treatment/control classification was 68.8% at Day2 and 87.5% at Day9; in contrast, the Day2/Day9 accuracy were 62.5%/87.5% using tumor mean [Formula: see text] and its CV and were 50.0%/87.5% using tumor mean [Formula: see text] and its CV, respectively. These results suggest that the SS model parameters outperformed the Tofts model parameters in terms of capturing bevacizumab therapeutic effect in this longitudinal experiment.
More Related Videos
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
09:04In Vivo Tracking of Edema Development and Microvascular Pathology in a Model of Experimental Cerebral Malaria Using Magnetic Resonance Imaging
Published on: June 8, 2017