Challenges in HbA1c Analysis and Reporting in Patients with Variant Hemoglobins

T A Sultana1, Z A Sheme, G S Sultana

  • 1Dr Tanvira Afroze Sultana, Assistant Professor, Department of Haematology, BIRDEM General Hospital, Shahbagh, Dhaka, Bangladesh.

Hemoglobin A1c (HbA(1)c) is a well-established indicator of mean glycemia. The presence of genetic variants of hemoglobin can profoundly affect the accuracy of HbA(1)c measurements. Variants of hemoglobin especially Hemoglobin E (HbE) is prevalent in South East Asia including Bangladesh. The objective of our study is to compare the HbA(1)c values measured on high performance liquid chromatography (HPLC) and Turbidimetric Inhibition Immunoassay (TINIA) in diabetic patients with variant hemoglobins including HbE. A total of 7595 diabetic patients receiving treatment at BIRDEM General Hospital were analyzed for HbA(1)c results within a period of two months from December 2013 to January 2014. Seventy two cases out of 7595 (0.95%) had either undetectable or below normal HbA(1)c levels (males-33 and females-39; ratio = 0.82:1) by HPLC method. In 34(0.45%) cases, HbA(1)c value was undetectable by HPLC method but was in the reportable range by TINIA method. In the other 38 (0.55%) cases, HbA(1)c levels were below the reportable range (<4%) by HPLC method but were in the normal or higher range by TINIA method. TINIA method did not agree with HPLC method on Bland Altman plot in the 38 cases with below normal HbA(1)c levels, [Mean bias -5.2(-9.3 to 1.0), 95% CI] but agreed very well [mean bias -0.21 (-0.84 to 0.42), y=1.1037+0.776X; r(2)=0.30, p<0.01] in controls. In control group mean MCV was 83.80±7.48 and in study group was 73.65±10.44. Alkaline electrophoresis confirmed the variant hemoglobin to be HbE. The fasting blood sugar levels of all the 72 cases correlated strongly with TINIA method (r(2) =0.75, p<0.0001) but not with HPLC (r = 0.24, p=0.13). In our regions where populations have a high prevalence of Hb variant, proper knowledge of hemoglobin variants which affect the measurements HbA(1)c level is essential. MCV of 80fl or below may serve as a rough guide to select samples that require analysis by TINIA method. Moreover, HPLC may be a convenient and inexpensive tool for screening of hemoglobinopathies especially among diabetic population in Bangladesh. It may therefore be helpful in improving management of complications related to both anaemia and iron overload.

Related Concept Videos

Multiple Allele Traits01:49

Multiple Allele Traits

The Concept of Multiple Allelism
38.6K
Variability: Analysis01:11

Variability: Analysis

Measures of variability are statistical metrics that reveal the dispersion pattern within a dataset. They are pivotal in biostatistics, providing insights into the heterogeneity within health and biological data. Variability signifies the degree to which data points diverge from one another, helping researchers understand the potential range of values and associated uncertainty within the data.
The range is a simple measure of variability, indicating the difference between the highest and...
618
Hemoglobin01:24

Hemoglobin

Hemoglobin is a globular protein made up of four subunits. Two of these subunits are alpha chains, and the other two are beta chains. Each subunit contains a molecule of heme, which has an iron atom and can bind to oxygen. When an oxygen molecule binds to one heme group, it changes the shape of hemoglobin, making it easier for the other heme groups to bind oxygen as well.
When all four heme groups are bound to oxygen, the resulting molecule is called oxyhemoglobin. As a result, arterial blood...
9.7K
Diabetes Mellitus: Type 2 and Gestational01:22

Diabetes Mellitus: Type 2 and Gestational

Type 2 diabetes, characterized by insulin resistance, arises when the insulin receptors on cells lose responsiveness to insulin, diminishing the cell's capacity to take up glucose, resulting in elevated blood glucose levels. To receive a diagnosis of Type 2 diabetes, a series of blood glucose tests are necessary to assess whether the blood glucose falls within normal parameters. If the result is out of the normal range, a patient may be diagnosed as prediabetic or diabetic, depending on the...
5.4K
Blood Typing01:10

Blood Typing

Understanding an individual's blood group is a critical component of transfusion medicine. It ensures compatibility in blood transfusions, organ transplants, and even during pregnancy. Determining these blood groups involves the ABO and Rh blood typing systems, utilizing specific antigens and corresponding anti-sera to identify an individual's blood type.
Antigens are protein molecules that reside on the surface of red blood cells (RBCs). The ABO and Rh blood typing systems target...
3.6K
Errors occurring during blood pressure monitoring01:25

Errors occurring during blood pressure monitoring

Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
1.7K