Related Experiment Video
Updated: Mar 19, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Leadless Cardiac Devices-Pacemakers and Implantable Cardioverter-Defibrillators
Hans Rutzen-Lopez1, Jose Silva1, Robert H Helm2
1Division of Cardiology, Boston University School of Medicine, Boston Medical Center, 88 E. Newton Street, Boston, MA, 02118, USA.
Opinion Statement:
Since the initial introduction of pacemakers and defibrillators, the rapid growth in microcircuit and battery technology has increased the longevity demands and exposed the vulnerabilities of transvenous leads. Over a half of century later, leadless pacemaker and defibrillation systems are just reaching the clinical arena. Despite the remarkable advantages of leadless pacing systems, the data are still quite limited and broad implementation of these technologies need to occur in a cautious and deliberate fashion as the peri-procedural risks remains high. Two of the three systems, Nanostim(TM) (St. Jude Medical) and Micra Transcatheter Pacing System (Medtronic Inc.), have shown the greatest applicability, although they are currently only limited to single chamber pacing and procedural risks are modest. The WiCS(TM)-LV system (EBR Systems, Inc.) is anatomically limited and benefits a small subset of patients. Leadless implantable cardioverter-defibrillator (ICD) therapy, the subcutaneous ICD (S-ICD, Cameron Health/Boston Scientific), has demonstrated encouraging short-term safety and efficacy data supporting its use. Since its introduction, modifications to the implant procedure, pre-screening of patients, and programming of the devices have reduced procedural-related complications and inappropriate shocks. The S-ICD is a promising technology, but it is premature to conclude that it will supplant conventional ICDs. At this current time, the S-ICD may benefit select patients, such as those with recurrent bacteremia, vascular access limitations, and who may be prone to transvenous lead failure.
More Related Videos
10:05Testing the Efficacy of Pharmacological Agents in a Pericardial Target Delivery Model in the Swine
Published on: July 7, 2016
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Cardiopulmonary Resuscitation III: AED Use
Heart Failure VI: Adjunct Therapies
Dysrhythmias VI: Management of Dysrhythmias
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiac Catheterization I: Pre-Procedure Overview