Double Invasive Blood Pressure Monitoring for Cesarean Delivery in a Pregnant Woman With Aortic Coarctation
Bruno Mendonça Barcellos1, Fernanda Martins Loureiro, Livia Fernandes Sampaio
1From the *Department of Anesthesiology, and †Department of Obstetrics and Gynecology, Hospital Universitário Antônio Pedro, Rio de Janeiro, Brazil.
Abstract:
Aortic coarctation is a discrete narrowing of the proximal thoracic aorta. It is poorly tolerated during pregnancy because of its association with hypertension, cerebrovascular accident, and aortic rupture. We report a case of severe uncorrected congenital aortic coarctation in a 31-year-old symptomatic pregnant woman at 29 weeks of gestation who underwent successful cesarean delivery with an epidural anesthetic technique. Transthoracic echocardiography showed a gradient of 75 mm Hg. To avoid undiagnosed arterial hypotension and inadequate uteroplacental flow distal to the coarctation, double (radial and femoral) invasive arterial blood pressure measurement was used to monitor both pre- and postcoarctation arterial blood pressure.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Aneurysm IV: Nursing Management
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.