Related Experiment Video
Updated: Mar 19, 2026

Precision Measurements and Parametric Models of Vertebral Endplates
Published on: September 17, 2019
Cervical pedicle morphometry in a Latin American population: A Brazilian study
Carlos Fernando Herrero1, Anderson Luis do Nascimento, Daniel Augusto Carvalho Maranho
1Department of Biomechanics, Medicine, and Rehabilitation of the Locomotor System Ribeirão Preto Medical School Radiology Division of the Internal Medicine Department, Ribeirão Preto Medical School, São Paulo, Brazil.
Abstract:
The goal of this study was to conduct a detailed computed tomography (CT) assessment in the Brazilian population of the screw starting point, trajectory, and dimensions of pedicle in the cervical spine.Two hundred consecutive patients were retrospectively evaluated using cervical spine CT, with imaging reconstruction of each cervical vertebrae in the axial plane with 2 mm, and in sagittal reconstructions with 3 mm. Parameters in axial plane included the pedicle width (PW), pedicle axis length (PAL), pedicle transverse angle (PTA), and the distance from the entry point to the point between the lamina and spinous process (DEP). Measurements in the sagittal plane involved the pedicle height (PH) and the pedicle sagittal angle (PSA).The mean PW and PH were smaller in females than in males in all cervical vertebrae, but there were no significant differences of PTA among genders. PSA ranged from 15.2° to 23.7°. Mean values of PAL and DEP had a tendency to decrease from the proximal to distal cervical vertebrae. PW was <4 mm in 7.5% of men (C3) and 25% of women (C3), and <4.5 mm in 20% (C3 male) and 66% (C3 female). The intra- and inter-observer reliability were very good for the tomographic measurement of PW, and good for PH. For PAL, the intraobserver reliability was good, but the interobserver reliability varied from moderate to good. Considering PTA and PSA, the intraobserver reliability was good, but the interobserver reliability moderate for PTA and poor or fair for PSA. DEP measurements showed poor intraobserver reliability, and poor or moderate interobserver reliability.Our results presented similar trend of previous studies, but the frequency of patients with PW <4.5 mm in our population is higher, suggesting an increased risk during the attempting of transpedicular screw technique.
More Related Videos
09:07An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
08:03Midface Hypoplasia and Cranial Base Morphology in Syndromic Craniosynostosis: A Comparative Analysis Study Using a Predictive Regression Model
Published on: November 4, 2025
Related Concept Videos
Vertebral Column: Regions and Curvature
Regions of the Vertebral Column
In an adult, the spine is subdivided into five regions: the cervical, the thoracic, the lumbar, the sacral, and the coccygeal region. The spine initially develops as a series of 33 vertebrae; after 20 years of age, the nine bones in the sacral region, five sacral, and four coccygeal bones fuse to form...
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...