Related Experiment Video
Updated: Mar 18, 2026

Extraction of Organochlorine Pesticides from Plastic Pellets and Plastic Type Analysis
Published on: July 1, 2017
Organophosphate Flame Retardants and Plasticizers in Aqueous Solution: pH-Dependent Hydrolysis, Kinetics, and
Guanyong Su1,2, Robert J Letcher1,2, Hongxia Yu3
1Ecotoxicology and Wildlife Health Division, Environment and Climate Change Canada, National Wildlife Research Centre, Carleton University , Ottawa, Ontario K1A 0H3, Canada.
Abstract:
Despite the growing ubiquity of organophosphate (OP) triesters as environmental contaminants, parameters affecting their aquatic chemical stabilities are currently unknown. The present study examined the pH-dependent (7, 9, 11, or 13) hydrolysis of 16 OP triesters in mixtures of 80 ng/mL for each OP triester over a period of 35 days at 20 °C. For the pH = 7, 9, and 11 solutions, 10 of the 16 OP triesters were stable and with no significant (p > 0.05) degradation. For the remaining 6 OP triesters, significant degradation occurred progressing from the pH = 7 to 11 solutions. At pH = 13, except for tributyl phosphate and tris(2-ethylhexyl) phosphate, 14 OP triesters were degraded with half-lives ranging from 0.0053 days (triphenyl phosphate) to 47 days (tripropyl phosphate). With increasingly basic pH the order of OP triester stability was group A (with alkyl moieties) > group B (chlorinated alkyl) > group C (aryl). Numerous OP diesters were identified depending on the pH level of the solution, whereas OP monoesters were not detectable. This is consistent with no significant (p > 0.05) depletion observed for 5 OP diesters in the same 4 solutions and over same 35 day period, suggesting OP diesters are end products of base-catalyzed hydrolysis of OP triesters. Our results demonstrated that pH-dependent hydrolysis of OP triesters does occur, and such instability would likely affect the fate of OP triesters in aqueous environments where the pH can be variable and basic.
More Related Videos
06:35Implementation of a Hyperbolic Vortex Plasma Reactor for the Removal of Micropollutants in Water
Published on: July 25, 2025
08:21Optimized Procedure for Determining the Adsorption of Phosphonates onto Granular Ferric Hydroxide using a Miniaturized Phosphorus Determination Method
Published on: May 18, 2018
Related Concept Videos
Microbial Bioremediation of Pesticides
Variables Affecting Phosphorescence and Fluorescence
Anticholinesterase Agents: Poisoning and Treatment
Irreversible agents form a strong bond with the cholinesterase enzyme, making it inactive. The breakdown of the phosphorylated enzyme is...
SN2 Reaction: Kinetics
In a chemical reaction, a relationship exists between the concentration of reactants and the rate at which the reaction proceeds. The study to measure this relationship is known as the kinetics of a chemical reaction. Kinetic studies are used to deduce the rate law of a chemical reaction, which provides information about the species involved during the transition state of the rate-determining step. Thus, kinetic studies help to derive the mechanism of a...
Predicting Reaction Outcomes
ortho–para-Directing Deactivators: Halogens