Related Experiment Video
Updated: Jun 25, 2026

Molecular Beam Mass Spectrometry With Tunable Vacuum Ultraviolet (VUV) Synchrotron Radiation
Published on: October 30, 2012
The vacuum ultraviolet beamline/endstations at NSRL dedicated to combustion research
Zhongyue Zhou1, Xuewei Du2, Jiuzhong Yang2
1School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, People's Republic of China.
Abstract:
An undulator-based vacuum ultraviolet (VUV) beamline (BL03U), intended for combustion chemistry studies, has been constructed at the National Synchrotron Radiation Laboratory (NSRL) in Hefei, China. The beamline is connected to the newly upgraded Hefei Light Source (HLS II), and could deliver photons in the 5-21 eV range, with a photon flux of 10(13) photons s(-1) at 10 eV when the beam current is 300 mA. The monochromator of the beamline is equipped with two gratings (200 lines mm(-1) and 400 lines mm(-1)) and its resolving power is 3900 at 7.3 eV for the 200 lines mm(-1) grating and 4200 at 14.6 eV for the 400 lines mm(-1) grating. The beamline serves three endstations which are designed for respective studies of premixed flame, fuel pyrolysis in flow reactor, and oxidation in jet-stirred reactor. Each endstation contains a reactor chamber, an ionization chamber where the molecular beam intersects with the VUV light, and a home-made reflectron time-of-flight mass spectrometer. The performance of the beamline and endstations with some preliminary results is presented here. The ability to detect reactive intermediates (e.g. H, O, OH and hydroperoxides) is advantageous in combustion chemistry research.
More Related Videos
10:04Flame Experiments at the Advanced Light Source: New Insights into Soot Formation Processes
Published on: May 26, 2014
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
Related Concept Videos
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab