Related Experiment Video
Updated: Mar 18, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Intraoperative fluoroscopic assessment of proper prosthetic radial head height
H Mike Kim1, Evan P Roush1, Casey Kiser1
1Department of Orthopaedics and Rehabilitation, Penn State College of Medicine, Milton S. Hershey Medical Center, Hershey, PA, USA.
Background:
Selecting a properly sized radial head prosthesis is imperative during radial head replacement. Although there has been much emphasis on avoiding overlengthening of the radius, little has been studied about how to avoid shortening. The purpose of this study was to characterize how a radial head replacement appears on intraoperative fluoroscopy depending on the height of the prosthetic radial head.
Methods:
Articular cartilage thickness of the radial head was measured in 9 cadaveric elbows. Radial head replacement was performed in each specimen with 4 different prosthetic head heights: 4 mm and 2 mm shortening, anatomic, and 2 mm overlengthening. Anteroposterior fluoroscopic images were obtained for each head height, and the prosthetic radial head height was measured at 3 forearm positions (supination, neutral, and pronation) using the subchondral bone of the lateral edge of the coronoid at the reference point.
Results:
The mean cartilage thickness of the radial head was 1.3 ± 0.4 mm. The prosthetic radial head appeared 2.2 ± 0.4 mm more proximal than the subchondral bone of the coronoid lateral edge in anteroposterior radiographs when the articular surface of the prosthesis was completely even with the coronoid articular surface. Unlike the native radial head, a prosthetic radial head showed a significant change of height with different forearm rotation (P < .001).
Discussion:
This study found that a perfectly anatomic radial head replacement appears overlengthened by approximately 2 mm in intraoperative radiographs. This finding can be useful in guiding the appropriate height of a prosthetic radial head.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: