Related Experiment Video
Updated: Mar 18, 2026

A Computer-Based Platform for Aiding Clinicians in Eating Disorder Analysis and Diagnosis
Published on: May 10, 2022
Developing a Digital Medicine System in Psychiatry: Ingestion Detection Rate and Latency Period
Deborah Profit1,2, Shashank Rohatagi2, Cathy Zhao2
1Otsuka Pharmaceutical Development & Commercialization, Inc, 508 Carnegie Center Blvd, Ste 300, Princeton, NJ 08540. debbie.profit@otsuka-us.com.
Background:
A digital medicine system (DMS) has been developed to measure and report adherence to an atypical antipsychotic, aripiprazole, in psychiatric patients. The DMS consists of 3 components: ingestible sensor embedded in a medication tablet, wearable sensor, and secure mobile and cloud-based applications. An umbrella study protocol was designed to rapidly assess the technical performance and safety of the DMS in multiple substudies to guide the technology development.
Methods:
Two sequential substudies enrolled 30 and 29 healthy volunteers between March-April 2014 and February-March 2015, respectively, to assess detection accuracy of the ingestible sensor by the DMS and the latency period between ingestion and detection of the ingestion by the wearable sensor or the cloud-based server.
Results:
The first substudy identified areas for improvement using early versions of the wearable sensor and the mobile application. The second substudy tested updated versions of the components and showed an overall ingestion detection rate of 96.6%. Mean latency times for the signal transmission were 1.1-1.3 minutes (from ingestion to the wearable sensor detection) and 6.2-10.3 minutes (from the wearable sensor detection to the server detection). Half of transmissions were completed in < 2 minutes, and ~90% of ingestions were registered by the smartphone within 30 minutes of ingestion. No serious adverse events, discontinuations, or clinically significant laboratory/vital signs findings were reported.
Conclusions:
The DMS implementing modified versions of the smartphone application and the wearable sensor has the technical capability to detect and report tablet ingestion with high accuracy and acceptable latency time.
Trial Registration:
ClinicalTrials.gov identifier: NCT02091882.
More Related Videos
Related Concept Videos
Pharmaceutical Poisoning: Potential Scenarios
Oral Drug Delivery Systems: Continuous-Release Systems
Psychosis: Goals of Pharmacotherapy
Prevention of Further Absorption of Poison
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Oral Drug Delivery Systems: Delayed-Release Systems

