Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Fully parametric imaging with reversible tracer 18F-FLT within a reasonable time
Nobuyuki Kudomi1, Yukito Maeda2, Tetsuhiro Hatakeyama3
1Department of Medical Physics, Faculty of Medicine, Kagawa University, Mikicho, Kagawa, 761-0793, Japan. kudomi@med.kagawa-u.ac.jp.
Abstract:
PET enables quantitative imaging of the rate constants K 1, k 2, k 3, and k 4, with a reversible two tissue compartment model (2TCM). A new method is proposed for computing all of these rates within a reasonable time, less than 1 min. A set of differential equations for the reversible 2TCM was converted into a single formula consisting of differential and convolution terms. The validity was tested on clinical data with 18F-FLT PET for patients with glioma (n = 39). Parametric images were generated with the formula that was developed. Parametric values were extracted from regions of interest (ROIs) for glioma from the images generated, and they were compared with those obtained with the non-linear fitting method. We performed simulation studies for testing accuracy by generating simulated images, assuming clinically expected ranges of the parametric values. The computation time was about 20 s, and the quality of the images generated was acceptable. The values obtained for K 1 for grade IV tumor were 0.24 ± 0.23 and 0.26 ± 0.25 ml-1 min-1 g-1 for the image-based and ROI-based methods, respectively. The values were 0.21 ± 0.12 and 0.21 ± 0.12 min-1 for k 2, 0.13 ± 0.07 and 0.13 ± 0.07 min-1 for k 3, and 0.052 ± 0.020 and 0.054 ± 0.021 min-1 for k 4. The differences between the methods were not significant. Regression analysis showed correlations of r = 0.94, 0.86, 0.71, and 0.52 for these parameters. Simulation demonstrated that the accuracy was within acceptable ranges, namely, the correlations were r = 0.99, r = 0.97, r = 0.99, and r = 0.91 for K 1, k 2, k 3, and k 4, respectively, between estimated and assumed values. This results suggest that parametric images can be obtained fully within reasonable time, accuracy, and quality.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)