Study on stability of DMS meridian detector
Ning Yang1, Li Huang2, Jiamin Yuan2
1Department of rehabilitation medicine, People's Hospital of Zhengzhou, Zhengzhou, Henan Province, PR China.
Pakistan Journal of Pharmaceutical Sciences
|July 8, 2016
Summary
The study investigated daily changes in acupuncture point conductance, finding significant variations. These findings are crucial for understanding meridian detector stability and traditional Chinese medicine principles.
Area of Science:
- Integrative Medicine
- Biophysics
- Traditional Chinese Medicine
Background:
- Ancient texts describe bodily fluid fluctuations correlating with meridians and time.
- These fluctuations are theorized to cause changes in skin conductance at acupuncture points.
- Modern instruments suggest meridian detector readings vary over 24 hours.
Purpose of the Study:
- To assess the statistical significance of conductance value changes in human acupuncture points over a 24-hour period.
- To analyze the stability of meridian detectors used in conductance measurements.
- To explore the relationship between qi, blood, and meridian conductance.
Main Methods:
- Utilized a DMS meridian detector to measure conductance values.
- Focused measurements on the twelve meridian jingyuan acupuncture points.
- Collected data over a 24-hour timeframe to capture daily variations.
Main Results:
- Observed statistically significant changes in acupuncture point conductance values within a 24-hour period.
- Demonstrated that meridian detector readings are not constant and fluctuate daily.
- Confirmed the dynamic nature of meridian point conductance.
Conclusions:
- Daily fluctuations in acupuncture point conductance are statistically significant.
- Meridian detector stability is influenced by daily physiological changes.
- Findings support the concept of time-dependent variations in the body's meridian system.
Related Concept Videos
Chemical Shift: Internal References and Solvent Effects
1.6K
In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
1.6K
Meridians
1.0K
In surveying, meridians are vital reference lines to measure directions and establish accurate land orientations. Meridians run from the north to the south poles, providing a stable framework for angular measurements and mapping. Meridians are fundamental in survey design, with the primary types being astronomic, magnetic, and assumed meridians. Each type offers distinct benefits and limitations, selected based on the project's scale and precision needs.The astronomic meridian is aligned with...
1.0K
NMR Spectroscopy: Chemical Shift Overview
3.8K
The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
For instance, the proton...
3.8K
Gas Chromatography: Types of Detectors-II
1.4K
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
1.4K


