Nasal high flow nebulization in infants and toddlers: An in vitro and in vivo scintigraphic study
Related Experiment Video
Updated: Mar 18, 2026

A Minimally Invasive Method for Intratracheal Instillation of Drugs in Neonatal Rodents to Treat Lung Disease
Published on: August 4, 2021
François Réminiac1,2,3,4, Laurent Vecellio1,2,5, Ronan Mac Loughlin6
1Université François Rabelais, Tours, France.
Abstract:
Aerosol therapy in infants and toddlers is challenging. Nebulization within a nasal high flow (NHF) circuit is attractive. The aim of this study was to quantify aerosol lung deposition when combined with NHF as compared with standard practice. Lung doses were measured scintigraphically after nebulization with jet and mesh nebulizer placed within a NHF circuit in a spontaneously breathing non-human primate model (macaque) and in the anatomical bench SAINT model, respectively representing a full-term newborn and a 9-month-old toddler. In the SAINT model, lung depositions observed with the mesh nebulizer placed in the NHF circuit set at 2 and 4 L/min were 3.3% and 4.2% of the nebulizer charge, respectively, and similar to the 1.70% observed with the control standard facemask jet nebulization (6 L/min flow). In the macaque model, the depositions observed with the mesh nebulizer in the NHF circuit set at 2 and 4 L/min were 0.49% and 0.85%, respectively, also similar to the control measurement (0.71%). Mesh nebulization within a NHF circuit set at 8 L/min and jet nebulization either within a NHF circuit or placed on top of the cannula (NHF set at 2 L/min; total flow of 8 L/min), resulted in a significantly lower lung depositions. Mesh nebulization within a NHF circuit delivering up to 4 L/min gas is likely to be at least as effective than jet nebulization with a facemask in infants and toddlers. Aerosol facemask placement on top of cannulas or jet nebulization within the NHF circuit may be less effective. Pediatr Pulmonol. 2017;52:337-344. © 2016 Wiley Periodicals, Inc.
More Related Videos
07:28Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Inhaled Medications
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Upper Respiratory Drugs: Antitussives, Expectorants, and Mucolytics
Antitussives include codeine, dextromethorphan (Robitussin), and benzonatate (Tessalon). Codeine and dextromethorphan exert their effects centrally by suppressing the cough reflex center in the medulla. Benzonatate operates peripherally within the respiratory tract by...