Radial artery perforation treated with balloon tracking and guide catheter tamponade - A case series

Sudhakar George1, Mamas Mamas2, James Nolan2

  • 1Royal Stoke University Hospital, Stoke-on-Trent, United Kingdom.

Insights

A novel technique using balloon assisted tracking and guide catheter tamponade successfully treated radial artery perforation during angioplasty. This approach allowed for the completion of the coronary angioplasty procedure via the radial artery, sealing the perforation.

Area of Science:

  • Interventional Cardiology
  • Vascular Surgery

Background:

  • Radial artery access is a common approach for coronary angiography and angioplasty.
  • Radial artery perforation is a rare but serious complication that can occur during these procedures.

Observation:

  • A 78-year-old woman experienced radial artery perforation during angioplasty via the left radial artery.
  • Extravasation of contrast confirmed the guide catheter-induced perforation.

Findings:

  • A technique combining balloon assisted tracking and guide catheter tamponade was employed.
  • This method successfully completed the angioplasty and sealed the radial artery perforation.
  • The technique was successfully applied in a series of 7 cases.

Implications:

  • This technique offers a potential solution for managing radial artery perforation during angioplasty.
  • It enables the completion of procedures via the radial artery, potentially reducing the need for conversion to other access sites.