Related Experiment Video
Updated: Mar 17, 2026

Procedure and Key Optimization Strategies for an Automated Capillary Electrophoretic-based Immunoassay Method
Published on: September 10, 2017
Comparison of Fully Automated and Semiautomated Systems for Protein Immunofixation Electrophoresis
Cecilia Napodano1, Krizia Pocino1, Francesca Gulli2
1School of Medicine, Department of Laboratory Medicine, Catholic University of the Sacred Heart, Rome, Italy.
Background:
In order to establish a diagnosis of monoclonal gammopathy, it is necessary to detect and identify monoclonal components. To confirm the immunological nature of the proteins, the next step is to define their composition in heavy and light chains using immunofixation. The purpose of this study was to compare two different instruments, one semiautomated and the other fully automated for serum and urine immunofixation.
Methods:
We selected 150 sera and 100 urines from patients admitted for routine analysis, which were analyzed by immunofixation to characterize monoclonal components.
Results And Conclusion:
Comparison study showed a difference in the identification of small monoclonal components and hypogammaglobulinemia, in serum and urine, between the two analyzers. We also observed a difference in the length of the electrophoretic pattern that is of considerable importance as it leads to a better resolution of the gamma region, allowing to identify even the smallest monoclonal component that can be easily hide in an oligoclonal pattern. For this reason, there is need to ameliorate commercial immunofixation assays. It is essential to improve data harmonization and standardize measurement procedures in order to guarantee a correct diagnosis for the right patient care.
More Related Videos
07:58Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
Published on: September 19, 2018
08:17A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood
Published on: February 8, 2016
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Immunoprecipitation
Chromatin Immunoprecipitation
Chromatin immunoprecipitation, also known as ChIP, is used to study protein-DNA or...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...