Related Experiment Video
Updated: Mar 17, 2026

Determining Pain Detection and Tolerance Thresholds Using an Integrated, Multi-Modal Pain Task Battery
Published on: April 14, 2016
Resting blood pressure differentially predicts time course in a tonic pain experiment
Bjoern Horing1, James A McCubbin2, Dewayne Moore2
1Department of Psychology, Clemson University, Clemson, South Carolina, USA. bhoring@clemson.edu.
Abstract:
Resting blood pressure (BP) shows a negative relationship with pain sensitivity (BP-related hypoalgesia). In chronic pain conditions, this relationship is inverted. The precise mechanisms responsible for the inversion are unknown. Using a tonic pain protocol, we report findings closely resembling this inversion in healthy participants. Resting BP and state measures of anxiety and mood were assessed from 33 participants (21 female). Participants then immersed their dominant hand in painfully hot water (47 °C) for five trials of 1-min duration, with 30-s intertrial intervals. Throughout the trials, participants continually registered their pain. After a 35-min intermission, the trial sequence was repeated. A disassociation of the negative relationship of resting systolic BP (as per Trial 1) was found using hierarchical linear modeling (p < .001, R(2) = .07). The disassociation unfolds over each consecutive trial, with an increasingly positive relationship. In Sequence 2, the initially negative relationship is almost completely absent. Furthermore, the association of BP and pain was found to be moderated by anxiety, such that only persons with low anxiety exhibited BP hypoalgesia. Our findings expand the existing literature by incorporating anxiety as a moderator of BP hypoalgesia. Furthermore, the protocol emulates the changing relationship between BP and pain observed in chronic pain patients. The protocol has potential as a model for chronic pain; however, future research should determine if similar physiological systems are involved. The finding holds potential diagnostic or prognostic relevance for certain clinical pain conditions, especially those involving dysfunction of the descending modulation of pain.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure

