Related Experiment Video
Updated: Mar 17, 2026

Portable Thermographic Screening for Detection of Acute Wallenberg's Syndrome
Published on: September 19, 2019
Thermographic analysis and autonomic response in the hands of patients with leprosy
Aretusa Lopes Cavalheiro1, Debora Tacon da Costa1, Ana Luiza Ferro de Menezes1
1Universidade Federal de Uberlândia (UFU) - Uberlândia (MG), Brazil.
Background:
Low temperatures and slow blood flow may result from peripheral neuropathy caused by leprosy, and the simple detection of cold fingers could already be a preliminary classification for these patients.
Objective:
To investigate whether infrared thermography would be able to measure this change in temperature in the hands of people with leprosy.
Method:
The study assessed 17 leprosy patients who were under treatment at the National Reference Center for Sanitary Dermatology and Leprosy, Uberlândia/MG, and 15 people without leprosy for the control group. The infrared camera FLIR A325 and Therma CAM Researcher Professional 2.9 software were used to measure the temperature. The room was air-conditioned, maintaining the temperature at 25°C; the distance between the camera and the limb was 70 cm. The vasomotor reflex of patients was tested by a cold stress on the palm.
Results:
The study showed a significant interaction between the clinical form of leprosy and temperature, where the control group and the borderline-borderline form revealed a higher initial temperature, while borderline-lepromatous and lepromatous leprosy showed a lower temperature. Regarding vasomotor reflex, lepromatous leprosy patients were unable to recover the initial temperature after cold stress, while those with the borderline-tuberculoid form not only recovered but exceeded the initial temperature.
Conclusion:
Thermography proved a potential tool to assist in the early detection of neuropathies, helping in the prevention of major nerve damage and the installation of deformities and disabilities that are characteristic of leprosy.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Thermosensation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...