Related Experiment Video
Updated: Dec 25, 2025

A Structured Approach to Extubation in Mechanically Ventilated Rats
Published on: July 18, 2025
Mechanical ventilation weaning practices in neonatal and pediatric ICUs in Brazil: the Weaning Survey-Brazil
Suzi Laine Longo Dos Santos Bacci1, Cíntia Johnston2, Wallisen Tadashi Hattori3
1. Programa de Pós-Graduação em Ciências da Saúde, Faculdade de Medicina, Universidade Federal de Uberlândia, Uberlândia (MG) Brasil.
Insights
Mechanical ventilation weaning practices in Brazil vary by ICU type. Pediatric ICUs favor spontaneous breathing trials, while neonatal ICUs use gradual withdrawal, indicating age-specific approaches to patient care.
Area of Science:
- Critical Care Medicine
- Pediatric Pulmonology
- Neonatal Medicine
Background:
- Mechanical ventilation (MV) is a critical support in intensive care units (ICUs).
- Weaning from MV requires specific protocols and methods for successful patient recovery.
- Variations in weaning practices may impact patient outcomes across different age groups.
Purpose of the Study:
- To describe the current practices for weaning from mechanical ventilation (MV).
- To analyze the use of protocols, methods, and criteria in pediatric ICUs (PICUs), neonatal ICUs (NICUs), and mixed neonatal/pediatric ICUs (NPICUs) in Brazil.
- To identify variations in weaning strategies based on ICU population age.
Main Methods:
- A cross-sectional survey was conducted.
- An electronic questionnaire was distributed to 298 NICUs, PICUs, and NPICUs across Brazil.
- Data from 146 completed questionnaires were analyzed.
Main Results:
- Weaning protocols were utilized in 57.5% of surveyed units.
- Standardized gradual withdrawal was common in NICUs (60.5%) and NPICUs (50.0%), while spontaneous breathing trials (SBTs) predominated in PICUs (53.0%).
- Clinical evaluation and arterial blood gas analysis are frequently used for extubation readiness assessment, irrespective of ICU age group.
Conclusions:
- Mechanical ventilation weaning and extubation practices in Brazil show variation based on the ICU's patient age group.
- Weaning protocols and SBTs are more prevalent in PICUs.
- Gradual withdrawal of ventilatory support is more commonly applied in NICUs and NPICUs.
Objective:
The aim of this study was to describe practices for weaning from mechanical ventilation (MV), in terms of the use of protocols, methods, and criteria, in pediatric ICUs (PICUs), neonatal ICUs (NICUs), and mixed neonatal/pediatric ICUs (NPICUs) in Brazil.
Methods:
This was a cross-sectional survey carried out by sending an electronic questionnaire to a total of 298 NICUs, PICUs, and NPICUs throughout Brazil.
Results:
Completed questionnaires were assessed for 146 hospitals, NICUs accounting for 49.3% of the questionnaires received, whereas PICUs and NPICUs accounted for 35.6% and 15.1%, respectively. Weaning protocols were applied in 57.5% of the units. In the NICUs and NPICUs that used weaning protocols, the method of MV weaning most commonly employed (in 60.5% and 50.0%, respectively) was standardized gradual withdrawal from ventilatory support, whereas that employed in most (53.0%) of the PICUs was spontaneous breathing trial (SBT). During the SBTs, the most common ventilation mode, in all ICUs, was pressure-support ventilation (10.03 ± 3.15 cmH2O) with positive end-expiratory pressure. The mean SBT duration was 35.76 ± 29.03 min in the NICUs, compared with 76.42 ± 41.09 min in the PICUs. The SBT parameters, weaning ventilation modes, and time frame considered for extubation failure were not found to be dependent on the age profile of the ICU population. The findings of the clinical evaluation and arterial blood gas analysis are frequently used as criteria to assess readiness for extubation, regardless of the age group served by the ICU.
Conclusions:
In Brazil, the clinical practices for weaning from MV and extubation appear to vary depending on the age group served by the ICU. It seems that weaning protocols and SBTs are used mainly in PICUs, whereas gradual withdrawal from ventilatory support is more widely used in NICUs and NPICUs.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...