Related Experiment Video
Updated: Mar 17, 2026

Enrich and Expand Rare Antigen-specific T Cells with Magnetic Nanoparticles
Published on: November 17, 2018
Evaluation of magnetic particles modified with a hydrophobic charge-induction ligand for antibody capture
Jia-Li Gu1, Hong-Fei Tong2, Dong-Qiang Lin2
1College of Life Sciences, Huzhou University, Huzhou 313000, China.
Abstract:
Magnetic particles modified with 5-amino-benzimidazole (ABI), a ligand for hydrophobic charge-induction chromatography, were prepared and used for antibody capture. In this study, with IgG as the model target, and bovine serum albumin (BSA) as the model impurity, the separation mechanism and process of IgG was investigated. The adsorption isotherms of IgG and BSA were measured, and the effects of pH were investigated in the range of pH 4.0-8.0. The maximum adsorption capacity of IgG on the particles was 180mg/ml at pH 7.0, while low adsorption capacity of BSA (64mg/ml) was found at pH 7.0, resulting in good selectivity. The protein-ligand interactions were elucidated by adding NaCl and glycerol. The results indicated the hydrophobic interactions were the main forces for IgG-ligand association. Moreover, the batch uptake and desorption experiments demonstrated the fast adsorption and desorption processes for IgG separation. The purity of IgG separated from mimetic serum could reach 98.6%, and the purity of monoclonal antibody (mAb) from a cell culture supernatant was 97.1%. Magnetic particles with hydrophobic charge-induction ligands showed a robust performance and could purify antibody directly from the complicated feedstock without clarification, which would improve the efficiency of antibody purification.
More Related Videos
06:48Antibody Labeling with Fluorescent Dyes Using Magnetic Protein A and Protein G Beads
Published on: September 15, 2016
09:58Computer Numerical Control Micromilling of a Microfluidic Acrylic Device with a Staggered Restriction for Magnetic Nanoparticle-Based Immunoassays
Published on: June 23, 2022