Background:
Computed tomography (CT) of the cervical spine (C-spine) is routinely ordered for low-risk mechanisms of injury, including ground-level fall. Two commonly used clinical decision rules (CDRs) to guide C-spine imaging in trauma are the National Emergency X-Radiography Utilization Study (NEXUS) and the Canadian Cervical Spine Rule for Radiography (CCR).
Methods:
Retrospective cross-sectional study of 3,753 consecutive adult patients presenting to an urban Level I emergency department who received C-spine CT scans were obtained over a 6-month period. The primary outcome of interest was prevalence of C-spine fracture. Secondary outcomes included fracture stability, appropriateness of imaging by NEXUS and CCR criteria, and estimated radiation dose exposure and costs associated with C-spine imaging studies.
Results:
Of the 760 patients meeting inclusion criteria, 7 C-spine fractures were identified (0.92% ± 0.68%). All fractures were identified by NEXUS and CCR criteria with 100% sensitivity. Of all these imaging studies performed, only 69% met NEXUS indications for imaging (50% met CCR indications). C-spine CT scans in patients not meeting CDR indications were associated with costs of $15,500 to $22,000 by NEXUS ($14,600-$25,600 by CCR) in this single center during the 6-month study period.
Conclusion:
For ground-level fall, C-spine CT is overused. The consistent application of CDR criteria would reduce annual nationwide imaging costs in the United States by $6.8 to $9.6 million based on NEXUS ($6.4-$15.6 million based on CCR) and would reduce population radiation dose exposure by 0.8 to 1.1 million mGy based on NEXUS (0.7-1.9 million mGy based on CCR) if applied across all Level I trauma centers. Greater use of evidence-based CDRs plays an important role in facilitating emergency department patient management and reducing systemwide radiation dose exposure and imaging expenditures.
Level Of Evidence:
Diagnostic study, level III.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT