Purpose:
To assess comfort and procedural facility using a 25-gauge trocar cannula as a port to diagnose and treat acute endophthalmitis compared with a standard vitreous tap and injection technique.
Methods:
Eighteen consecutive patients with acute endophthalmitis were randomized into two treatment arms: 1) Standard vitreous tap and injection technique, and 2) A technique where a valved 25-gauge trocar cannula is inserted through the pars plana as done in sutureless vitrectomy surgery and subsequent vitreous sampling and injections are performed through the port. A standardized anesthetic protocol was used and subjects were masked to the technique performed. Primary outcomes measured were patient comfort using a Wong-Baker pain scale and standardized physician ease-of-use scoring scale. Secondary outcomes included vitreous sampling success rate and volume of vitreous sample.
Results:
No significant differences were found when comparing patient comfort (P = 0.340), physician ease-of-use scores (P = 0.796), vitreous sample volume (P = 0.149), successful vitreous taps (P = 0.620), and microbiologic yield (P = 1.000) between treatment arms. There were no adverse events.
Conclusion:
The 25-gauge trocar technique provides a safe, well-tolerated, and equally effective alternative to the standard vitreous tap and injection technique for delivery of intravitreal antibiotics, and procuring of vitreous sample, requiring a single sharp penetration.