Related Experiment Video
Updated: Mar 17, 2026

Asymmetrical Flow Field-Flow Fractionation for Sizing of Gold Nanoparticles in Suspension
Published on: September 11, 2020
Techniques for Accurate Sizing of Gold Nanoparticles Using Dynamic Light Scattering with Particular Application to
Tianyu Zheng1, Steven Bott2, Qun Huo1
1NanoScience Technology Center and Department of Chemistry, University of Central Florida , 12424 Research Parkway Suite 400, Orlando, Florida 32826, United States.
Abstract:
Gold nanoparticles (AuNPs) have found broad applications in chemical and biological sensing, catalysis, biomolecular imaging, in vitro diagnostics, cancer therapy, and many other areas. Dynamic light scattering (DLS) is an analytical tool used routinely for nanoparticle size measurement and analysis. Due to its relatively low cost and ease of operation in comparison to other more sophisticated techniques, DLS is the primary choice of instrumentation for analyzing the size and size distribution of nanoparticle suspensions. However, many DLS users are unfamiliar with the principles behind the DLS measurement and are unware of some of the intrinsic limitations as well as the unique capabilities of this technique. The lack of sufficient understanding of DLS often leads to inappropriate experimental design and misinterpretation of the data. In this study, we performed DLS analyses on a series of citrate-stabilized AuNPs with diameters ranging from 10 to 100 nm. Our study shows that the measured hydrodynamic diameters of the AuNPs can vary significantly with concentration and incident laser power. The scattered light intensity of the AuNPs has a nearly sixth order power law increase with diameter, and the enormous scattered light intensity of AuNPs with diameters around or exceeding 80 nm causes a substantial multiple scattering effect in conventional DLS instruments. The effect leads to significant errors in the reported average hydrodynamic diameter of the AuNPs when the measurements are analyzed in the conventional way, without accounting for the multiple scattering. We present here some useful methods to obtain the accurate hydrodynamic size of the AuNPs using DLS. We also demonstrate and explain an extremely powerful aspect of DLS-its exceptional sensitivity in detecting gold nanoparticle aggregate formation, and the use of this unique capability for chemical and biological sensing applications.
More Related Videos
08:21A Simple Method for the Size Controlled Synthesis of Stable Oligomeric Clusters of Gold Nanoparticles under Ambient Conditions
Published on: February 5, 2016
09:16Measurement of Particle Size Distribution in Turbid Solutions by Dynamic Light Scattering Microscopy
Published on: January 9, 2017