Establishing a reproducible protocol for measuring index active extension strength.
V Matter-Parrat1, J J Hidalgo Diaz1, S Collon2
11 Department of Hand Surgery, University Hospital of Strasbourg, Illkirch, France.
The Journal of Hand Surgery, European Volume
|July 31, 2016
Summary
This study developed a reproducible protocol to measure index finger extension strength. The new method proved reliable, showing no significant difference based on hand dominance.
Area of Science:
- Biomechanics
- Musculoskeletal Research
- Hand Function Assessment
Background:
- Accurate measurement of index finger extension strength is crucial for clinical assessment and rehabilitation.
- Existing protocols may lack reproducibility or fail to differentiate between independent and dependent index finger movements.
- Understanding the influence of hand dominance on index finger strength is important for targeted interventions.
Purpose of the Study:
- To establish a reproducible protocol for measuring active index finger extension strength.
- To correlate index finger extension strength with other finger contraction forces and assess the role of hand dominance.
- To evaluate the reproducibility of the developed measurement protocol.
Main Methods:
- A protocol was developed to measure independent and dependent index finger extension strength using a dynamometer.
- Measurements were taken on 24 healthy volunteers (19 women, 20 right-handed) by three examiners on two separate days.
- Intra-examiner and inter-examiner reliability were assessed.
Main Results:
- The developed protocol demonstrated high intra-examiner (>0.90) and inter-examiner (>0.75) reproducibility.
- Independent index extension strength was found to be lower than dependent strength.
- No significant differences in either independent or dependent index extension strength were observed between dominant and non-dominant hands.
Conclusions:
- The established protocol is reproducible for measuring both independent and dependent index finger extension strength.
- Hand dominance does not appear to influence index finger extension strength.
- This reliable protocol can be utilized for clinical and research applications in hand function assessment.