Related Experiment Video
Updated: Mar 16, 2026

Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Rapid Voltammetric Measurements at Conducting Polymer Microelectrodes Using Ultralow-Capacitance
Adam R Meier1, Marco Matteucci2, Richard F Vreeland1
1Department of Chemistry and Biochemistry, University of Arizona , 1306 East University Boulevard, Tucson, Arizona 85721, United States.
Unlabelled:
We use a vapor-phase synthesis to generate conducting polymer films with low apparent capacitance and high conductance enabling rapid electrochemical measurements. Specifically, oxidative chemical vapor deposition was used to create thin films of poly(3,4-ethylenedioxythiophene):tosylate (
Pedot:
tosylate). These films had a conductance of 17.1 ± 1.7 S/cm. Furthermore, they had an apparent capacitance of 197 ± 14 μF/cm(2), which is an order of magnitude lower than current commercially available and previously reported PEDOT. Using a multistage photolithography process, these films were patterned into
Pedot:
tosylate microelectrodes and were used to perform fast-scan cyclic voltammetry (FSCV) measurements. Using a scan rate of 100 V/s, we measured ferrocene carboxylic acid and dopamine by FSCV. In contrast to carbon-fiber microelectrodes, the reduction peak showed higher sensitivity when compared to the oxidation peak. The adsorption characteristics of dopamine at the polymer electrode were fit to a Langmuir isotherm. The low apparent capacitance and the microlithographic processes for electrode design make
Pedot:
tosylate an attractive material for future applications as an implantable biosensor for FSCV measurements. Additionally, the integration of
Pedot:
tosylate electrodes on plastic substrates enables new electrochemical measurements at this polymer using FSCV.
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetry: Factors Affecting Measurements
Voltammetric Techniques: Cyclic Voltammetry

