Lessons learnt from the radiological measures performed by the Radiological Emergency Network of Extremadura in the
A Baeza1, J A Corbacho1, J M Caballero1
1Faculty of Veterinary Sciences, Environmental Radioactivity Laboratory, University of Extremadura, 10003 Cáceres, Spain.
None:
In late 2013 (5th-7th of November), the Cáceres Urgent Response International Exercise (CURIEX 2013) took place to test the Nuclear Emergency Plan of Cáceres (PENCA) with the collaboration of both national and international support teams. The theme of the exercise was the simulation of a nuclear accident at the Almaraz Nuclear Power Plant located in Extremadura (Spain) with release of radioactive plume. From the point of view of radioactive contamination, the CURIEX exercise objective was to assess the capability of the different radiological teams to quantify the radioactive impact that would occur in this environment, a goal in which the Radiological Emergency Network of Extremadura (RARE) is directly implicated. The present paper analyses in detail the environmental radiological and dosimetrical results obtained by the Radiological Emergency Network of Extremadura during the CURIEX exercise. The rapid radioactivity measurement techniques on air and soil samples performed by the RARE's mobile lab involves great uncertainties. However, the results show a relative good effectiveness both in dose rate car-borne measurements and gamma soil spectrometry with uncertainties over 40%. It also shows a good correlation between the dose rate values measured by car-borne apparatus and those calculated from gamma spectrometry measurements. The capability of the RARE's facilities are evaluated in both the measurements, showing whether or not there is a radiological problem, and the transmission of that data to the decision centres in the shortest time. Although the results were highly satisfactory, some shortcomings were detected and therefore some improvements are proposed in the paper, in order to achieve a greater capacity in response to an event with the characteristics simulated in the CURIEX exercise.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
X-ray Imaging
Absorption of Radiation