In vitro aerodynamic characteristics of aerosol delivered from different inhalation methods in mechanical ventilation
Muhammad H E ElHansy1, Marina E Boules2, Heba Farid3
1a Department of Clinical Pharmacy, Teaching Hospital of Faculty of Medicine , Fayoum University , Fayoum , Egypt.
Abstract:
Aerodynamic characteristics of aerosol delivery during invasive mechanical ventilation (IMV) are mostly determined by inserting cascade impactor in the circuit. Impactor might have some effect on airflow within IMV. Hence, the aim of the present study was to develop and evaluate new in vitro aerodynamic characterization methodology without affecting airflow in IMV. Breathing simulator was set in standard adult IMV circuit with inspiratory and expiratory pressures of 20 and 5 cm H2O, 1:3 inspiratory-expiratory ratio, 15 breaths min-1, and tidal volume of 500 ml. Two ml of salbutamol solution containing 10,000 μg was nebulized using three different vibrating mesh nebulizers (VMNs) and Sidestream jet nebulizer (JET). Sixteen-metered doses, containing 100 μg salbutamol each, were delivered using three different spacers. Each device was placed in inspiration limb of Y-piece of ventilator tubing. Aerodynamic characteristics of aerosol delivered were measured using cooled Andersen cascade impactor, with mixing inlet connected to it. VMNs used had significantly more total mass in the impactor (p < .001) and fine particle dose (p < .001) compared to JET. Spacers used had higher total mass in the impactor percent (p < .001) and fine particle fraction compared to nebulizers. The in vitro IMV methodology setting suggested here showed encouraging results in comparison of different aerosol delivery systems in intubated patient.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Inhaled Medications