Diagnostic hepatic haemodynamic techniques: safety and radiation exposure
Andrej Hari1, Hari Kumar Nair1, Andrea De Gottardi1
1Swiss Liver Center, Hepatology, University Clinic for Visceral Surgery and Medicine, Inselspital, University of Berne, Berne, Switzerland.
Background & Aims:
Hepatic venous pressure gradient (HVPG) and transjugular liver biopsy (TJLB) are increasingly used in the management of patients with liver disease. We aimed to describe the safety profile of these procedures, providing data on the intra- and periprocedure complications, radiation exposure and amount of iodinated contrast material used.
Methods:
In 106 consecutive patients undergoing HVPG and TJLB data on fluoroscopy time (FT), absorbed radiation dose, equivalent effective dose (mSv) and volume of iodinated contrast material (ICM) were prospectively collected and reviewed, together with clinical and laboratory data. Incidence and severity of procedure-related complications were assessed. In 28 hospitalised patients, creatinine values after 72 hours of the procedure were reviewed to identify contrast-induced nephropathy (CIN).
Results:
Median effective radiation dose was 5.4 mSv (IQR 10 mSv). A total 28.3% of patients exceeded an effective exposure of 10 mSv and 9.4% exceeded 20 mSv. Only age and BMI correlated with radiation dose (R = .327, P=.001 and R = .410, P<.0001 respectively), and only BMI remained independently associated with an exposure over 20 mSv. Procedure-related complications occurred in eight patients (7.5%), and were minor in six cases. Median ICM volume was 12.5 mL. 6/28 patients met the diagnostic criteria for CIN.
Conclusions:
Hepatic venous pressure gradient and Transjugular liver biopsy show a good safety profile and radiation exposure associated with these procedures is in most of the cases low. In hepatic haemodynamic procedures, efforts should be made to reduce the radiation dose in patients with overweight/obesity and to use the minimal possible ICM volume in patients with acute-on-chronic liver failure.
Related Concept Videos
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies VII: Vascular Imaging