Related Experiment Video
Updated: Mar 16, 2026

Setting Up a Stroke Team Algorithm and Conducting Simulation-based Training in the Emergency Department - A Practical Guide
Published on: January 15, 2017
Quality improvement utilizing in-situ simulation for a dual-hospital pediatric code response team
Phoebe Yager1, Corey Collins2, Carlene Blais2
1MassGeneral Hospital for Children, 175 Cambridge Street, CPZS-5, Boston, MA 02114, USA.
Objective:
Given the rarity of in-hospital pediatric emergency events, identification of gaps and inefficiencies in the code response can be difficult. In-situ, simulation-based medical education programs can identify unrecognized systems-based challenges. We hypothesized that developing an in-situ, simulation-based pediatric emergency response program would identify latent inefficiencies in a complex, dual-hospital pediatric code response system and allow rapid intervention testing to improve performance before implementation at an institutional level.
Methods:
Pediatric leadership from two hospitals with a shared pediatric code response team employed the Institute for Healthcare Improvement's (IHI) Breakthrough Model for Collaborative Improvement to design a program consisting of Plan-Do-Study-Act cycles occurring in a simulated environment. The objectives of the program were to 1) identify inefficiencies in our pediatric code response; 2) correlate to current workflow; 3) employ an iterative process to test quality improvement interventions in a safe environment; and 4) measure performance before actual implementation at the institutional level.
Results:
Twelve dual-hospital, in-situ, simulated, pediatric emergencies occurred over one year. The initial simulated event allowed identification of inefficiencies including delayed provider response, delayed initiation of cardiopulmonary resuscitation (CPR), and delayed vascular access. These gaps were linked to process issues including unreliable code pager activation, slow elevator response, and lack of responder familiarity with layout and contents of code cart. From first to last simulation with multiple simulated process improvements, code response time for secondary providers coming from the second hospital decreased from 29 to 7 min, time to CPR initiation decreased from 90 to 15 s, and vascular access obtainment decreased from 15 to 3 min. Some of these simulated process improvements were adopted into the institutional response while others continue to be trended over time for evidence that observed changes represent a true new state of control.
Conclusions:
Utilizing the IHI's Breakthrough Model, we developed a simulation-based program to 1) successfully identify gaps and inefficiencies in a complex, dual-hospital, pediatric code response system and 2) provide an environment in which to safely test quality improvement interventions before institutional dissemination.
Related Concept Videos
Health Information Technology and Healthcare Information System
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include:
Hospitals-II
Nurses that work in...
Integrated Healthcare System
Methods Of Healthcare Delivery System
Managed Care System:
The managed care system is designed to control the cost while maintaining the quality of care. The patient's care from admission to discharge is planned by the primary care provider or the case manager, also known as the gatekeeper. In a managed care system, the number of care providers is...
Acute Kidney Injury V: Interprofessional Care
Nursing Implementation
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.