Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
Flow characteristics around proximal and distal stenoses in a series of tandem stenosed vessels
Hyung Kyu Huh1, Woo Rak Choi1, Hojin Ha2
1Center for Biofluid and Biomimic Research, Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang 790-784, South Korea.
Abstract:
The flow characteristics around the proximal and distal stenoses in tandem vessel models are experimentally investigated with varying flow rates (Q=0.25, 0.5, 1.0L/min), interspacing distances (L=3, 6, 10 of diameter D) and severities (S=50%, 75% reduction in diameter). When the interspacing L is larger than 10 D, no fluid-dynamic interaction is observed. The flow between the proximal and distal stenoses becomes stabilized (turbulence intensity of <3%) as the interspacing distance decreases. When the severity S is 75%, the transition from laminar to turbulent flow occurs at a flow rate higher than 0.5L/min, although the interspacing distance L is 3 D. Formation of recirculation flow is restricted by the presence of distal stenosis as the interspacing distance decreases. In this case, the flow between the stenoses is focused on the central region. The center-line velocity at the neck of the distal stenosis is approximately 10-15% higher than that of the proximal stenosis with equal severity of S=50%. When the inlet flow is center-focused, the lengths of the recirculation and the jet core behind the distal stenosis increase with decrease in interspacing distance L. When the inlet flow is turbulent, the transition from laminar to turbulent flow occurs early as the interspacing distance L is reduced. When the upstream proximal stenosis exhibits increased severity, the pressure drop is measured to be 20% compared with that when the severity of the downstream distal stenosis is increased at the flow rate of Q=1.0L/min.
More Related Videos
12:00Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
Related Concept Videos
Mitral Stenosis I: Introduction
Mitral Stenosis II: Clinical features and Diagnostic Tests
Anastomoses
Anastomoses can be formed at arterial, venous, and lymphatic vessels.
Arterial Anastomosis: These occur between arteries. They...