Related Experiment Video
Updated: Mar 16, 2026

Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
Published on: January 17, 2025
Cone Beam CT Versus Multislice CT: Radiologic Diagnostic Agreement in the Postoperative Assessment of Cochlear
Victor Razafindranaly1, Eric Truy, Jean-Baptiste Pialat
1*Hospices Civils de Lyon, University Hospital Edouard Herriot, Lyon †Department of Otolaryngology, pavillon U ‡Department of Radiology, pavillon B §Cellule Recherche du PAM Imagerie ||Pôle Information Médicale Evaluation Recherche, Hospices Civils de Lyon, Lyon, France.
Objective:
To evaluate the diagnostic concordance between multislice computed tomography (MSCT) and cone beam computed tomography (CBCT) in the early postoperative assessment of patients after cochlear implantation.
Study Design:
Prospective, randomized, single-center, interventional, pilot study on the diagnostic performance of a medical device.
Setting:
Tertiary referral center.
Patients:
Patients aged over 18 years requiring a computed tomographic (CT) scan after cochlear implant surgery.
Interventions:
Nine patients were implanted with electrode arrays from three different manufacturers, including one bilateral. High-resolution MSCT and CBCT were then performed, and two experienced radiologists blinded to the imaging modality evaluated the randomized images, twice.
Main Outcome Measures:
Concordance between MSCT and CBCT for assessing the scalar position (tympani or vestibuli) of the electrodes. Secondary outcome measures were also studied: length of the intracochlear electrode array, percentage of implanted cochlea, number of intracochlear electrodes, and radiation doses.
Results:
There was a good agreement between both CT scanners in determining the scalar position and estimating the number of implanted electrodes and percentage of implanted cochlea. CBCT had a lower radiation exposure.
Conclusions:
The CBCT appears to be a useful tool for postoperative assessment of cochlear implanted adult patients and is comparable to the conventional scanner in determining the scalar position, with lower radiation exposure.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

