Related Experiment Video
Updated: Mar 16, 2026
![Measuring the Spin-Lattice Relaxation Magnetic Field Dependence of Hyperpolarized [1-13C]pyruvate](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F59399.jpg&w=3840&q=50)
Measuring the Spin-Lattice Relaxation Magnetic Field Dependence of Hyperpolarized [1-13C]pyruvate
Published on: September 13, 2019
Adiabatically prepared spin-lock approach for T1ρ-based dynamic glucose enhanced MRI at ultrahigh fields
Patrick Schuenke1, Christina Koehler2, Andreas Korzowski1
1German Cancer Research Center (DKFZ), Division of Medical Physics in Radiology, Heidelberg, Germany.
Purpose:
Chemical exchange sensitive spin-lock and related techniques allow to observe the uptake of administered D-glucose in vivo. The exchange-weighting increases with the magnetic field strength, but inhomogeneities in the radiofrequency (RF) field at ultrahigh field whole-body scanners lead to artifacts in conventional spin-lock experiments. Thus, our aim was the development of an adiabatically prepared T1ρ -based imaging sequence applicable to studies of glucose metabolism in tumor patients at ultrahigh field strengths.
Methods:
An adiabatically prepared on-resonant spin-lock approach was realized at a 7 Tesla whole-body scanner and compared with conventional spin-lock. The insensitivity to RF field inhomogeneities as well as the chemical exchange sensitivity of the approach was investigated in simulations, model solutions and in the human brain.
Results:
The suggested spin-lock approach was shown to be feasible for in vivo application at ultrahigh field whole-body scanners and showed substantially improved image quality compared with conventional spin-lock. The sensitivity of the presented method to glucose was verified in model solutions and a glucose contrast was observed in a glioblastoma patient after intravenous administration of glucose solution.
Conclusion:
An adiabatically prepared spin-lock preparation was presented that enables a homogeneous and chemical exchange sensitive T1ρ -based imaging at ultra-high field whole-body scanners, e.g., for T1ρ -based dynamic glucose enhanced MRI. Magn Reson Med 78:215-225, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Related Concept Videos
Magnetic Resonance Imaging
Atomic Nuclei: Magnetic Resonance
Atomic Nuclei: Nuclear Relaxation Processes
Atomic Nuclei: Types of Nuclear Relaxation
In spin–lattice or longitudinal relaxation, the excited spins exchange energy with the surrounding lattice as they return to the lower energy level. Among several mechanisms that contribute to spin–lattice relaxation, magnetic dipolar interactions are significant. Here, the excited nucleus transfers...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Atomic Nuclei: Nuclear Spin State Population Distribution

