Related Experiment Video
Updated: Mar 16, 2026

09:01
Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
12.5K
Three Methods Of Guided Growth For Pediatric Lower Extremity Angular Deformity Correction
Pooya Hosseinzadeh1, David R Ross2, Janet L Walker2
1Baptist Children's Hospital, Miami, FL.
The Iowa Orthopaedic Journal
|August 17, 2016
Summary
Stainless steel Pedi-plates demonstrate fewer complications and faster angular deformity correction in guided growth procedures compared to titanium staples and eight-plates. This finding aids in selecting optimal implants for pediatric orthopedic interventions.
Area of Science:
- Orthopedic Surgery
- Pediatric Orthopedics
- Biomaterials Science
Background:
- Guided growth is a surgical technique used to correct angular deformities in pediatric patients.
- Various implants, including titanium staples, titanium eight-plates, and stainless steel Pedi-plates, are employed for guided growth.
- Comparative data on the effectiveness and complication rates of these implants are limited in existing literature.
Purpose of the Study:
- To compare the effectiveness and complication rates of different guided growth implants.
- To evaluate the rate of angular deformity correction associated with each implant type.
- To provide evidence-based guidance for selecting appropriate implants in pediatric guided growth procedures.
Main Methods:
- A retrospective review of 77 pediatric patients undergoing guided growth procedures.
- Comparison of titanium staples, titanium eight-plates, and stainless steel Pedi-plates.
- Analysis of complication rates and rate of deformity correction over an average follow-up of 18 months.
Main Results:
- Stainless steel Pedi-plates exhibited a significantly lower complication rate compared to titanium staples and eight-plates.
- The stainless steel Pedi-plate group showed a significantly faster rate of angular deformity correction than the titanium staple group.
- No significant difference in complication rates or correction speed was noted between titanium eight-plates and titanium staples.
Conclusions:
- Stainless steel Pedi-plates represent a favorable option for guided growth due to lower complication rates and efficient deformity correction.
- The findings support informed decision-making for orthopedic surgeons when choosing implants for pediatric angular deformity correction.
- Further research may explore long-term outcomes and patient-reported satisfaction across different implant types.