Related Experiment Video
Updated: Mar 16, 2026

Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Extracorporeal membrane oxygenator support in infants with systemic-pulmonary shunts
Phil Botha1, Shriprasad R Deshpande1, Michael Wolf1
1Children's Healthcare of Atlanta, Emory University, Atlanta, Ga.
Background:
Management of a patent systemic-pulmonary (SP) shunt and the resulting runoff during extracorporeal membrane oxygenation (ECMO) varies among institutions. We have used a strategy of increased flow without surgical reduction of the shunt diameter, and here report our results with this strategy.
Methods:
In this database review of 169 successive veno-arterial ECMO runs performed between 2002 and 2013 in infants and neonates, ECMO flow, time to achieve lactate clearance, normal pH, and negative fluid balance were compared in patients with shunts and those without shunts.
Results:
Fifty-one of 169 infants (30.2%) had a shunt in situ when ECMO was initiated. Significantly higher ECMO flows were maintained in the shunt group compared with the nonshunt group (161 ± 43 mL/kg/minute vs 134 ± 41 mL/kg/minute; P < .001). Infants with shunts had significantly higher pre-ECMO and peak lactate levels (12.4 ± 5.6 mmol/L vs 10.0 ± 6.3 mmol/L; P < .05 and 13.7 ± 4.9 mmol/L vs 11.6 ± 5.5 mmol/L; P < .02, respectively) and required a longer period of support for clearance (median, 28.8 hours [16.1-63.3 hours] vs 17.5 hours [10.8-34.5 hours]; P < .001). Although the absolute rate of lactate clearance was not significantly different between the 2 groups (median, 0.46 mmol/L/hour [0.12-0.72 mmol/L/hour] vs 0.48 mmol/L/hour [0.22-0.86 mmol/L/hour]; P = .139) the presence of a shunt, neonatal age, peak lactate, extracorporeal cardiopulmonary resuscitation, and the use of hemofiltration on ECMO significantly predicted the rate of clearance. Survival to hospital discharge was similar in the shunt and nonshunt groups (49.0% vs 48.3%; P = .932).
Conclusions:
A strategy of increased ECMO flow without surgically restricting shunt diameter appears to be successful in providing circulatory support in the majority of patients with an SP shunt. Equivalent survival suggests that routine surgical reduction of shunt diameter is not indicated.
More Related Videos
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Acute Respiratory Failure-IV

