Related Experiment Video
Updated: Mar 16, 2026

07:24
Production of High-Titer Recombinant Newcastle Disease Virus from Allantoic Fluid
Published on: May 25, 2022
4.7K
Newly Developed Neutralized pH Icodextrin Dialysis Fluid: Nonclinical Evaluation
Naoya Yamaguchi1, Keiichi Miyamoto1, Tomohiro Murata2
1Department of Chemistry for Materials, Faculty of Engineering, Mie University.
Artificial Organs
|August 18, 2016
Summary
Neutralizing icodextrin peritoneal dialysis fluid (PDF) with the NICOPELIQ system preserves human peritoneal mesothelial cell viability and reduces cytotoxicity. This improved biocompatibility does not compromise the fluid
Area of Science:
- Biomaterials Science
- Nephrology
- Peritoneal Dialysis
Background:
- Icodextrin peritoneal dialysis fluid (PDF) is used for fluid management in patients undergoing peritoneal dialysis.
- Icodextrin PDFs can generate glucose degradation products (GDPs) and have a low pH, potentially affecting biocompatibility.
- A novel two-compartment system, NICOPELIQ (NICO), has been developed to neutralize icodextrin PDF.
Purpose of the Study:
- To conduct a nonclinical evaluation of the NICOPELIQ system for neutralizing icodextrin PDF.
- To assess the biocompatibility and water transport ability of neutralized icodextrin PDF.
- To analyze glucose degradation products (GDPs) and their impact on cell viability and cytotoxicity.
Main Methods:
- Analysis of GDPs in icodextrin PDFs using high-performance liquid chromatography (HPLC).
- Evaluation of human peritoneal mesothelial cell (PDE-HPMC) viability and lactate dehydrogenase (LDH) release after exposure to different PDFs (NICO, EXTRANEAL [EX], MIDPELIQ 250 [M250]).
- Assessment of water transport ability using dialysis membranes with varying pore sizes.
Main Results:
- Cell viability decreased by 30% after 30 min exposure to NICO but was maintained for 6 hours, unlike EXTRANEAL.
- No significant difference in cell viability was observed between NICO and EXTRANEAL when pH was adjusted, despite higher GDPs in EXTRANEAL.
- Reduced cell viability occurred below pH 6; LDH release was minimal (<5%) with NICO exposure. Water transport was comparable between NICO and EXTRANEAL.
Conclusions:
- Neutralization of icodextrin PDF using the NICOPELIQ system is beneficial for enhancing biocompatibility.
- The NICO system effectively maintains cell viability and minimizes cytotoxicity (LDH release).
- Neutralized icodextrin PDF demonstrates comparable water transport ability to conventional icodextrin PDF.
Related Concept Videos
Ion-Exchange Chromatography
2.7K
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
2.7K
Dialysis
2.1K
Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
2.1K
Peritoneal Dialysis I: Introduction and Procedure
5.3K
Peritoneal dialysis (PD) is a procedure that facilitates the exchange of solutes, waste products, electrolytes, and excess fluid between the blood in the peritoneal capillaries and a dialysis solution introduced into the peritoneal cavity.Principles of Peritoneal Dialysis (PD)Diffusion: Waste products such as urea and electrolytes move from high concentrations in the blood to low concentrations in the dialysate across the peritoneal membrane. This mechanism is driven by the concentration...
5.3K