A Coding System for Reoperations Following Total Ankle Replacement and Ankle Arthrodesis
Alastair S E Younger1, Mark Glazebrook2, Andrea Veljkovic3
1Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada asyounger@shaw.ca.
Foot & Ankle International
|August 18, 2016
Summary
A new classification system for ankle surgery reoperations shows total ankle replacement has higher reoperation rates than ankle arthrodesis. This system aids in understanding failure and improving future surgical outcomes.
Area of Science:
- Orthopedic Surgery
- Arthroplasty
- Reconstructive Surgery
Background:
- Repeated surgeries indicate primary surgical failure and incur significant costs.
- A standardized system is needed to classify and analyze reoperations in end-stage ankle arthritis.
- Existing classification systems may not adequately capture reoperation details for ankle procedures.
Purpose of the Study:
- To introduce a novel classification system for reoperations following end-stage ankle arthritis surgery.
- To analyze and compare reoperation rates between ankle arthrodesis and total ankle replacement.
- To establish the reliability of the new classification system for clinical use.
Main Methods:
- A prospective cohort study followed 213 ankle arthrodeses and 474 total ankle replacements from 2002-2010.
- Reoperations were identified, operating reports reviewed, and each coded using the new system.
- Inter- and intraobserver reliability of the coding system was assessed by 6 experienced surgeons.
Main Results:
- Overall, 74.8% of procedures required no reoperation.
- Total ankle replacement had a significantly higher reoperation rate (30.2%) compared to ankle arthrodesis (14.1%).
- Reoperations within the ankle joint were more common after total ankle replacement (26.1%) than arthrodesis (4.7%).
- The new coding system demonstrated high interobserver (ICC=0.89) and intraobserver (ICC=0.92) reliability.
Conclusions:
- The proposed classification system is reliable and offers a standardized framework for assessing ankle surgery reoperations.
- The system facilitates a better understanding of reoperation causes, potentially improving future surgical outcomes.
- Higher reoperation rates in total ankle replacement warrant further investigation into failure mechanisms.