An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
16.0K
Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants.
Yahya Açil1, Jan Sievers2, Aydin Gülses3
1Department of Oral and Maxillofacial Surgery, Christian-Albrecht-Universität zu Kiel, Kiel, Germany.
Odontology
|August 20, 2016
Summary
Resonance frequency analysis (RFA) shows a moderate correlation with bone-implant contact (BIC) immediately after dental implant placement. Peak insertion torque (PIT) did not show a significant correlation with either RFA or BIC.
Area of Science:
- Dental Implantology
- Biomaterials Science
- Histomorphometry
Background:
- Assessing initial implant stability is crucial for successful osseointegration.
- Resonance frequency analysis (RFA) and peak insertion torque (PIT) are common methods to evaluate primary stability.
- Histomorphometric bone-implant contact (BIC) provides a direct measure of osseointegration.
Purpose of the Study:
- To evaluate the correlation between RFA values and histomorphometric BIC immediately after implant insertion.
- To determine the correlation between PIT and BIC and RFA.
Main Methods:
- 15 dental implants were inserted into porcine bone.
- Insertion torque was measured, and RFA was recorded using Osstell® ISQ.
- Bone-implant contact (BIC) was assessed via histomorphometry after implant removal.
Main Results:
- A moderate, statistically significant positive correlation was found between RFA and BIC (R=0.579, p=0.026).
- No statistically significant correlation was observed between PIT and BIC (p>0.05).
- No statistically significant correlation was observed between PIT and RFA (p>0.05).
Conclusions:
- RFA is a moderately reliable indicator of initial bone-implant contact.
- PIT is not a reliable indicator of initial bone-implant contact or RFA in this model.
- Further research on varying bone qualities is recommended.
Keywords:
Bone-implant contactCorrelationDental implantsHistomorphometric measurementsImmediate loadingInsertion torquePrimary stabilityResonance frequency analysisMore Related Videos
Related Concept Videos
Screw: Problem Solving
758
In mechanical engineering, the interaction between a threaded screw shaft and a plate gear involves analyzing the resisting torque on the plate gear that can be overpowered when a specific torsional moment is applied to the shaft. To better comprehend this concept, consider a generic situation with a threaded screw shaft with a given mean radius and lead and a plate gear with a specified mean radius. The coefficient of static friction between the screw and gear is also provided.
To evaluate the...
To evaluate the...
758
Frictional Forces on Screws
1.7K
Screws are characterized by a helical ridge known as a thread wrapped around a cylindrical shaft. They are commonly used as fasteners to hold objects together or to transmit power and motion in machines. One type of screw that is particularly useful for transmitting power is the square-threaded screw.
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
1.7K
Residual Stresses in Circular Shafts
589
In materials that exhibit elastic and plastic behavior, known as elastoplastic materials, residual stresses can accumulate when these materials experience plastic deformation. This deformation arises from either high levels of shearing stress or significant strains. Residual stresses are internal stresses that persist within a material after removing the external force causing deformation. This phenomenon is demonstrated when observing the behavior of a shaft under torque; notably, the...
589