Flowcytometric comparative analysis in acute leukemias between Indian and proposed minimal screening panel
Srishti Gupta1, Tathagata Chatterjee2, Sanjeevan Sharma3
1Resident (Pathology), Army Hospital (R&R), New Delhi 110010, India.
Background:
Acute myeloid leukemia and acute lymphoid leukemia differ substantially in response to therapy and course, and accurate differentiation of the two is fundamental to therapeutic decisions. Immunophenotyping is used for this purpose, and various guidelines have been proposed regarding a minimal screening antibody panel. Most of them have been found inefficient.
Methods:
Eighty-two cases of consecutive acute leukemias reporting to this hospital over a period of two years were included in the study. Peripheral blood smear, bone marrow aspirate, and bone marrow biopsy were studied using morphology, cytochemical stains, and relevant immunohistochemical stains on selected biopsy specimens. Flowcytometry analysis was carried out using Indian consensus screening panel and our proposed minimal screening panel (PMSP) for comparison.
Result:
Immunophenotyping using PMSP resulted in 95.12% accurate diagnosis versus Indian consensus minimal screening panel (ICMSP) with an accuracy of 92.68%. This result was statistically significant as per Chi Square tests.
Conclusion:
PMSP can be used as a substitute for ICMSP, since it includes lineage-specific cytoplasmic antibodies, as well as lesser number of monoclonal antibodies, and enables us to diagnose mixed lineage leukemia. Fewer markers can be linked to a lower cost as well, which is relevant in a developing economy.
More Related Videos
09:01Flow Cytometry to Estimate Leukemia Stem Cells in Primary Acute Myeloid Leukemia and in Patient-derived-xenografts, at Diagnosis and Follow Up
Published on: March 26, 2018
07:38Intracellular Phosphoflow Cytometry of Acute Myeloid Leukemia Patient-Derived Xenotransplants
Published on: June 6, 2025