Related Experiment Video
Updated: Mar 15, 2026

Sediment Core Extrusion Method at Millimeter Resolution Using a Calibrated, Threaded-rod
Published on: August 17, 2016
Analytical approaches for determination of bromine in sediment core samples by X-ray fluorescence spectrometry
Galina V Pashkova1, Tatyana S Aisueva2, Alexander L Finkelshtein2
1Institute of the Earth's Crust, Siberian Branch of Russian Academy of Sciences, Lermontov st., 128, Irkutsk, 664033 Russian Federation.
Abstract:
Bromine has been recognized as a valuable indicator for paleoclimatic studies. Wavelength dispersive X-ray fluorescence (WDXRF) and total reflection X-ray fluorescence (TXRF) methods were applied to study the bromine distributions in lake sediment cores. Conventional WDXRF technique usually requires relatively large mass of a sediment sample and a set of calibration samples. Some analytical approaches were developed to apply WDXRF to small sediment core samples in the absence of adequate calibration samples with a known Br content. The mass of a sample to be analyzed was reduced up to 200-300mg and the internal standard method with correction using fundamental parameters was developed for Br quantification. TXRF technique based on the direct analysis of a solid suspension using 20mg of sediment sample by internal standard method was additionally tested. The accuracy of the WDXRF and TXRF techniques was assessed by the comparative analysis of reference materials of sediments, soil and biological samples. In general, good agreement was achieved between the reference values and the measured values. The detection limits of Br were 1mg/kg and 0.4mg/kg for WDXRF and TXRF respectively. The results of the Br determination obtained with different XRF techniques were comparable to each other and used for paleoclimatic reconstructions.
More Related Videos
Related Concept Videos
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Emission Spectroscopy: Lab
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Determination of Crystal Structures

