Related Experiment Video
Updated: Mar 15, 2026

High Content Screening Analysis to Evaluate the Toxicological Effects of Harmful and Potentially Harmful Constituents HPHC
Published on: May 10, 2016
RIFM fragrance ingredient safety assessment, 2-ethyl-1-hexanol, CAS registry number 104-76-7
This safety assessment confirms the material is safe for current use. Evaluations for genotoxicity, skin sensitization, and environmental safety showed no adverse effects, supporting its continued application.
Area of Science:
- Toxicology
- Chemical Safety Assessment
- Environmental Safety
Background:
- The safety of the material under current usage conditions requires comprehensive evaluation.
- Existing data and read-across approaches are utilized for toxicological assessments.
Purpose of the Study:
- To evaluate the genotoxicity, repeated dose toxicity, developmental toxicity, reproductive toxicity, local respiratory toxicity, phototoxicity, skin sensitization, and environmental safety of the material.
- To determine the safety profile of the material for its intended applications.
Main Methods:
- Genotoxicity assays were performed.
- Skin sensitization was assessed using read-across data from 2-butyloctan-1-ol (CAS # 3913-02-8).
- Reproductive and local respiratory toxicity were evaluated using the Threshold of Toxicological Concern (TTC) for Cramer Class I materials.
- Developmental and repeat dose toxicity were assessed using data on the target material.
- Phototoxicity/photoallergenicity was determined via UV spectra analysis.
- Environmental safety was evaluated according to the RIFM Framework.
Main Results:
- The material was found to be non-genotoxic.
- No skin sensitization potential was identified.
- The reproductive and local respiratory toxicity assessments yielded acceptable results based on TTC values.
- Developmental and repeat dose toxicity studies indicated a Margin of Exposure (MOE) greater than 100.
- Phototoxicity/photoallergenicity assessment was completed.
- Environmental safety evaluation was concluded.
Conclusions:
- The material is considered safe for use under current conditions.
- The comprehensive toxicological and environmental safety evaluations support the material's continued application.
- No significant safety concerns were identified across the evaluated endpoints.
More Related Videos
10:13Eye Irritation Test EIT for Hazard Identification of Eye Irritating Chemicals using Reconstructed Human Cornea-like Epithelial RhCE Tissue Model
Published on: August 23, 2015
09:54Synthesis and Characterization of 1,2-Dithiolane Modified Self-Assembling Peptides
Published on: August 20, 2018
Related Concept Videos
E2 Reaction: Stereochemistry and Regiochemistry
When a substrate with two different β hydrogens undergoes an E2 elimination, the presence of a strong base can yield two regioisomeric alkenes. The more-substituted alkene is the major...
Autoxidation of Ethers to Peroxides and Hydroperoxides