Related Experiment Video
Updated: Mar 15, 2026

Three-Dimensional Reconstruction of Orbital Fractures
Published on: May 16, 2025
Anatomical Studies of the Orbital Cavity Using Three-Dimensional Computed Tomography
Hyo-Sun Kang1, Jeong Joon Han, Hee-Kyun Oh
1*School of Dentistry, Chonnam National University†Department of Oral and Maxillofacial Surgery, Chonnam National University Hospital‡Department of Oral and Maxillofacial Surgery, School of Dentistry, Dental Science Research Institute, Chonnam National University, Gwangju, Korea.
Objective:
This study was designed to analyze the morphometric characteristics of the orbital cavity using three-dimensional computed tomography in Asians.
Methods:
Two hundred seventy-six orbits in 142 Asians (74 men and 68 women) were examined and compared according to age, sex, and laterality (right and left).
Results:
Mean orbital morphometric values were as follows. Orbital cavity depth was 49.60 mm from optic foramen to orbitale (inferior) and 41.32 mm from optic foramen to lacrimal crest (medial). Anterior and posterior orbital medial wall heights were 17.73 and 12.76 mm, respectively. Medial, middle, and lateral orbital floor lengths were 39.08, 29.56, and 20.08 mm, respectively. Anterior and posterior orbital floor width was 21.87 and 12.00 mm, respectively. For the orbital inferior-medial angle, anterior, middle, and posterior value was 132.11°, 126.24°, and 136.88°, respectively. Inferior orbital cavity depth, anterior orbital medial wall height, and orbital floor length tended to increase with aging, whereas orbital floor width tended to decrease with aging. No significant differences were found in terms of laterality, and values were greater in men than in women.
Conclusions:
This quantitative analysis of orbital measurements will allow surgeons to plan operations more accurately and will help predict outcomes.
More Related Videos
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Anatomy of the Eyeball
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET