Analytical elimination of substrate backside reflections from reflectance measurements
Applied Optics
|September 9, 2016
Abstract:
An analytical approach to eliminate substrate backside reflections from measured reflectance of an unknown optical coating has been deducted. Thereby, measured transmittance, reflectance, and backside reflectance of the coating and transmittance and reflectance of the uncoated substrate at the desired angle of incidence and polarization state are required as input data. In the underlying theory, layer and substrate materials may be absorbing.
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
1.5K
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
1.5K
Atomic Absorption Spectroscopy: Interference
2.3K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.3K
Elimination Reactions
18.1K
A nucleophile can react with an alkyl halide to give the substitution product by displacing the halogen. Or it can function as a base to give the elimination product by deprotonation of the neighboring carbon to form an alkene. In an elimination reaction, the substrate loses two groups from adjacent carbons forming at least one π bond. The carbon attached to the halogen is called the α carbon, while the adjacent carbon is called the β carbon; hence, these reactions are called...
18.1K
Blank Solutions
1.5K
A blank solution is a solution that does not contain the analyte, or the substance of interest being tested or measured. It is typically prepared using the same reagents and procedure as the sample solution but without adding the analyte. The primary purpose of preparing a blank solution is to account for any background interference or contamination that may affect the accuracy and reliability of the analytical method.
In some experimental cases, the reagents, solvents, or lab equipment used in...
In some experimental cases, the reagents, solvents, or lab equipment used in...