Towards chemical profiling of ignitable liquids with comprehensive two-dimensional gas chromatography: Exploring
Andjoe A S Sampat1, Martin Lopatka2, Gabriel Vivó-Truyols1
1vant Hoff Institute for Molecular Sciences, Faculty of Science, University of Amsterdam, P.O. Box 94157, 1090 GD Amsterdam, The Netherlands.
Abstract:
The application of GC×GC-FID and GC×GC-MS for the chemical analysis and profiling of neat white spirit is explored and the benefit of the enhanced peak capacity offered by comprehensive two-dimensional gas chromatography is demonstrated. An extensive sampling exercise was conducted throughout The Netherlands and the production and logistics in terms of bottling and distribution of white spirits were studied. An exploratory approach based on target-peak tables and principal component analysis was employed to study the brand-to-brand differences and production variations over time. Despite the complex chemical composition of white spirit samples this study shows that chemical variation during productions is actually quite limited. Hence care has to be taken with the chemical comparison for forensic purposes. Although some clustering was noticed on brand level, the large scale production process leads to a very consistent composition across stores and brands. However, because of the broad specifications of this commodity product, substantial chemical variation was found over time. This temporal discrimination could be of forensic value when considering white spirits supplies in individual households.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...