Aortic insufficiency in continuous-flow left ventricular assist device support patients is common but does not impact
Christopher T Holley1, Megan Fitzpatrick1, Samit S Roy2
1Department of Surgery, Division of Cardiovascular and Thoracic Surgery, University of Minnesota, Minneapolis, Minnesota, USA.
Background:
Aortic insufficiency (AI) is a significant long-term complication of continuous-flow left ventricular assist device (CF-LVAD) implantation. We sought to evaluate its impact on clinical outcomes and mortality in CF-LVAD recipients.
Methods:
We retrospectively analyzed 237 patients implanted with HeartMate II CF-LVADs at our institution from June 2005 through June 2013. We evaluated recipients' baseline characteristics and annual echocardiograms, grading AI severity as either none, trace, mild, moderate or severe. Only moderate or severe AI was considered clinically significant. Recipients who underwent concomitant aortic valve surgery or who had undergone previous prosthetic aortic valve implantation were excluded.
Results:
Moderate or severe AI occurred in 32 (15.2%) patients. Risk factors that significantly affected the development of AI included older age at the time of implantation, female gender, longer duration of LVAD support and destination therapy designation. Freedom from moderate or severe AI was 94%, 76% and 65% of patients at 1, 3 and 5 years, respectively. Overall cohort survival based on Kaplan-Meier analysis was 78%, 59% and 42% at 1, 3 and 5 years, respectively. There was no difference in survival between recipients who developed significant AI and those who did not (log-rank test, p = 0.73).
Conclusions:
In this large, single-institution study, the overall rate of AI was low, but increased in frequency with longer duration of LVAD support. Although AI development remains a concern for patients on long-term CF-LVAD support, AI development does not appear to impact long-term mortality.
More Related Videos
05:18Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026
07:41Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Aortic Regurgitation III: Medical Management
Aortic Regurgitation IV: Nursing Management
Aortic Regurgitation I: Introduction
Heart Failure VI: Adjunct Therapies
Aortic Regurgitation II: Clinical Features and Diagnostic Tests