Related Experiment Video
Updated: Mar 15, 2026

Large Scale Energy Efficient Sensor Network Routing Using a Quantum Processor Unit
Published on: September 8, 2023
Performance Analysis of Amplify-and-Forward Systems with Single Relay Selection in Correlated Environments
1Department of Nanobio Materials and Electronics, Gwangju Institute of Science and Technology, Gwangju 61005, Korea. binhnguyen@gist.ac.kr.
Abstract:
In this paper, we consider amplify-and-forward (AnF) cooperative systems under correlated fading environments. We first present a brief overview of existing works on the effect of channel correlations on the system performance. We then focus on our main contribution which is analyzing the outage probability of a multi-AnF-relay system with the best relay selection (BRS) scheme under a condition that two channels of each relay, source-relay and relay-destination channels, are correlated. Using lower and upper bounds on the end-to-end received signal-to-noise ratio (SNR) at the destination, we derive corresponding upper and lower bounds on the system outage probability. We prove that the system can achieve a diversity order (DO) equal to the number of relays. In addition, and importantly, we show that the considered correlation form has a constructive effect on the system performance. In other words, the larger the correlation coefficient, the better system performance. Our analytic results are corroborated by extensive Monte-Carlo simulations.
More Related Videos
09:09Foreign Accent and Forensic Speaker Identification in Voice Lineups: The Influence of Acoustic Features Based on Prosody
Published on: September 27, 2024
11:09RBDT: A Computerized Task System based in Transposition for the Continuous Analysis of Relational Behavior Dynamics in Humans
Published on: July 17, 2021
Related Concept Videos
Differential Relays
Directional Relays
Pilot and Numeric Relaying
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Overcurrent Relays
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...