Putative membrane lytic sites of P-type and S-type cardiotoxins from snake venoms as probed by all-atom molecular
Biswajit Gorai1, Muthusamy Karthikeyan2, Thirunavukkarasu Sivaraman3
1Structural Biology Lab, Department of Bioinformatics, School of Chemical and Biotechnology, SASTRA University, Thanjavur, 613 401, Tamil Nadu, India.
Abstract:
Cardiotoxins (CTXs) belonging to the three-finger toxin superfamily of snake venoms are one of principal toxic components and the protein toxins exhibit membrane lytic activities when the venoms are injected into victims. In the present study, complex formations between CTX VI (a P-type CTX from Naja atra) and CTX1 (an S-type CTX from Naja naja) on zwitterionic POPC bilayers (a major lipid component of cell membranes) have been studied in near physiological conditions for a total dynamic time scale of 1.35 μs using all-atom molecular dynamics (MD) simulations. Comprehensive analyses of the MD data revealed that residues such as Leu1, Lys2, Tyr11, Lys31, Asp57 and Arg58 of CTX VI, and Ala16, Lys30 and Arg58 of CTX1 were crucial for establishing interactions with the POPC bilayer. Moreover, loop I, along with globular head and loop II of CTX VI, and loop II of CTX1 were found to be the structural regions chiefly governing complex formation of the respective proteins with POPC. Rationalizations for the differential binding modes of CTXs and implications of the findings for designing small molecular inhibitors to the toxins are also discussed. Graphical Abstract Binding modes of a P-type CTX and an S-type CTX towards the POPC bilayer.
Related Concept Videos
Resting Membrane Potential
The Inside of a Neuron is More Negative
The membrane potential of a cell can be measured by inserting a microelectrode into a cell and comparing the charge to a reference electrode in the extracellular fluid. The...
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...


