Related Experiment Video
Updated: Aug 4, 2026

Absorption of Nasal and Bronchial Fluids: Precision Sampling of the Human Respiratory Mucosa and Laboratory Processing of Samples
Published on: January 21, 2018
A New Miniature Respirable Sampler for In-mask Sampling: Part 1-Particle Size Selection Performance
Peter Stacey1, Andrew Thorpe2, Rhiannon Mogridge2
11.Health and Safety Executive, Science Division, Health and Safety Laboratory, Harpur Hill, Buxton SK17 9JN, United Kingdom; peter.stacey@hsl.gsi.gov.uk.
Abstract:
The Health and Safety Laboratory has developed a miniature respirable sampler to gain a better understanding of the exposure of workers to hazardous substances when they are wearing respiratory protective equipment (RPE) or helmets with visors in the workplace. The study was in two parts and the first part, described herein, was to develop the sampler and test its collection characteristics. Assessment of the impact of the sampler on RPE safety and its comparability with traditional laboratory-based approaches to measure protection factors was discussed in a second article. The miniature sampler (weight-5.4g, length-13mm) was designed to fit into the space available between the nose and chin of an individual inside a filtering facepiece type mask and has a radially omnidirectional inlet with a porous foam particle selector that allows the collection of the respirable fraction on a downstream filter. The sampling efficiency was compared with the respirable convention. A close match with the respirable convention was obtained at a flow rate of 1 l min-1 and the 50% penetration cut off value (d 50) was 4.08 µm. After 3 hours sampling in high humidity (95%), the penetration curve had shifted towards smaller particle sizes (d 50 = 3.81 µm) with 88% of the calculated bias values within 10%. The miniature sampler measured respirable dust and crystalline silica mass concentrations comparable with performance of the Safety In Mines Personal Dust Sampler (SIMPEDS), commonly used in Great Britain, at a flow rate of 0.8 l min-1 The d 50 for the miniature sampler at 0.8 l min-1 (4.4 µm) is within 5% of the d 50 of the SIMPEDS at its prescribed flow rate of 2.2 l min-1 (4.2 µm). These results indicated that the miniature sampler was a good candidate to proceed with tests with RPE described in the second part of this series of two papers.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...

