Related Experiment Video
Updated: Mar 14, 2026

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
Published on: October 1, 2007
CZE-CZE ESI-MS Coupling with a Fully Isolated Mechanical Valve.
Felix J Kohl1, Christian Neusüß2
1Department of Chemistry, Aalen University, Beethovenstraβe 1, Aalen, D-73430, Germany.
This study introduces a two-dimensional capillary electrophoresis system to overcome electrospray ionization-mass spectrometry (ESI-MS) limitations. The method effectively removes interfering compounds, enabling robust peptide and protein analysis via ESI-MS.
Area of Science:
- Analytical Chemistry
- Biochemistry
- Proteomics
Background:
- Capillary electrophoresis coupled with electrospray ionization-mass spectrometry (CE-ESI-MS) is vital for peptide and protein analysis.
- Interference from background electrolytes in CE hinders direct ESI-MS coupling.
- Existing CE methods often require modification for MS compatibility.
Purpose of the Study:
- To develop a CE-ESI-MS compatible method for peptide and protein analysis.
- To address the challenge of interfering compounds in CE background electrolytes.
- To enable sensitive and selective detection and identification of analytes.
Main Methods:
- Implementation of a two-dimensional capillary electrophoresis (2D-CE) system.
- Utilizing the second dimension of CE as a cleanup stage.
- Optimizing separation and cleanup for MS detection.
Main Results:
- Successfully removed interfering compounds from CE background electrolytes.
- Enabled seamless coupling of CE with ESI-MS.
- Demonstrated effective peptide and protein analysis with high sensitivity and selectivity.
Conclusions:
- The developed 2D-CE system is a powerful tool for overcoming CE-ESI-MS compatibility issues.
- This approach enhances the applicability of CE for complex biological sample analysis.
- Facilitates reliable analyte identification in proteomics research.
Related Concept Videos
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Mechanical Systems
Electro-mechanical Systems
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
Multiple Pipe Systems
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...

