Related Experiment Video
Updated: Mar 14, 2026

Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Accuracy of Laboratory Data Communication on ICU Daily Rounds Using an Electronic Health Record
Kathryn A Artis1, Edward Dyer, Vishnu Mohan
11Division of Pulmonary and Critical Care Medicine, Department of Medicine, Oregon Health and Science University, Portland, OR. 2Section of Pulmonary and Critical Care Medicine, Division of Hospital and Specialty Care, Portland Veterans Administration Medical Center, Portland, OR. 3Department of Medical Informatics and Clinical Epidemiology, Oregon Health and Science University, Portland, OR.
Objectives:
Accurately communicating patient data during daily ICU rounds is critically important since data provide the basis for clinical decision making. Despite its importance, high fidelity data communication during interprofessional ICU rounds is assumed, yet unproven. We created a robust but simple methodology to measure the prevalence of inaccurately communicated (misrepresented) data and to characterize data communication failures by type. We also assessed how commonly the rounding team detected data misrepresentation and whether data communication was impacted by environmental, human, and workflow factors.
Design:
Direct observation of verbalized laboratory data during daily ICU rounds compared with data within the electronic health record and on presenters' paper prerounding notes.
Setting:
Twenty-six-bed academic medical ICU with a well-established electronic health record.
Subjects:
ICU rounds presenter (medical student or resident physician), interprofessional rounding team.
Interventions:
None.
Measurements And Main Results:
During 301 observed patient presentations including 4,945 audited laboratory results, presenters used a paper prerounding tool for 94.3% of presentations but tools contained only 78% of available electronic health record laboratory data. Ninty-six percent of patient presentations included at least one laboratory misrepresentation (mean, 6.3 per patient) and 38.9% of all audited laboratory data were inaccurately communicated. Most misrepresentation events were omissions. Only 7.8% of all laboratory misrepresentations were detected.
Conclusion:
Despite a structured interprofessional rounding script and a well-established electronic health record, clinician laboratory data retrieval and communication during ICU rounds at our institution was poor, prone to omissions and inaccuracies, yet largely unrecognized by the rounding team. This highlights an important patient safety issue that is likely widely prevalent, yet underrecognized.
Related Concept Videos
Methods of Documentation VII: EMR
Data Reporting and Recording
Purpose of Health Records I
Here's a breakdown of how health records serve these purposes:
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
SBAR I: Understanding the Concept
Standardized methods of communication have been developed to ensure that information is...
Introduction to Documentation and Reporting
Nursing documentation records essential information and details regarding a patient's care and treatment in written or electronic form. It is a critical aspect of nursing practice that involves documenting assessments, interventions, outcomes, and other relevant details about a patient's health status.
Documentation maps the patient's health journey by creating a comprehensive...