Related Experiment Video
Updated: Mar 14, 2026

Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
Can three-dimensional high-resolution anorectal manometry detect anal sphincter defects in patients with faecal
A Rezaie1, S Iriana2, M Pimentel1
1Division of Gastroenterology, Cedars Sinai Medical Center, Los Angeles, California, USA.
Aim:
Endoanal ultrasound (EAUS) is the gold standard for detecting anal sphincter defects in patients with faecal incontinence (FI), while anorectal manometry evaluates sphincter function. Three-dimensional high-resolution anorectal manometry (3D HRAM) is a newer modality with the potential to assess both sphincter function and anatomy. The purpose of the present study was to compare 3D HRAM with 3D EAUS for the detection of anal sphincter defects in patients with FI.
Method:
A linkage analysis was performed between the 3D HRAM and 3D EAUS databases of a tertiary referral centre to identify patients with FI who underwent both 3D EAUS and 3D HRAM. With 3D HRAM, a defect was defined as any pressure measurement below 25 mmHg at rest with at least 18° of continuous expansion. The 3D HRAM findings were compared with those of 3D EAUS.
Results:
The study cohort included 39 patients with a mean age of 64.7 ± 15.2 years (SD); and 31 (79%) were female. Eight (21%) patients had an anal sphincter defect on EAUS with a median size of 93° (range 40°-136°). Fourteen (36%) had a defect shown by 3D HRAM with a median size of 144° (36°-180°). The sensitivity, specificity and positive and negative predictive values of 3D HRAM in detecting a sphincter defect were 75%, 74%, 43% and 92%, respectively.
Conclusion:
With a negative predictive value of 92%, 3D HRAM may be a useful screening method for ruling out a sphincter defect in patients with FI, thereby avoiding both EAUS and manometry in selected patients.
More Related Videos
04:33Spinal Hernia Repair and Cauda Equina Repositioning After Lumbar Decompression under Three-Dimensional Microscopy: A Case Report and Literature Review
Published on: November 8, 2024
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Related Concept Videos
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Inflammatory Bowel Disease V: Surgical Management
Here are some common surgical interventions for IBD:
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies VI: Voiding Cystourethrography and Cystography