Related Experiment Video
Updated: Mar 14, 2026

Thermal Imaging to Study Stress Non-invasively in Unrestrained Birds
Published on: November 6, 2015
Is reticular temperature a useful indicator of heat stress in dairy cattle?
S Ammer1, C Lambertz2, M Gauly2
1Department of Animal Sciences, Georg-August-University, 37075 Goettingen, Germany.
Abstract:
The present study investigated whether reticular temperature (RT) in dairy cattle is a useful indicator of heat stress considering the effects of milk yield and water intake (WI). In total, 28 Holstein-Friesian dairy cows raised on 3 farms in Lower Saxony, Germany, were studied from March to December 2013. During the study, RT and barn climate parameters (air temperature, relative humidity) were measured continuously and individual milk yield was recorded daily. Both the daily temperature-humidity index (THI) and the daily median RT per cow were calculated. Additionally, the individual WI (amount and frequency) of 10 cows during 100d of the study was recorded on 1 farm. Averaged over all farms, daily THI ranged between 35.4 and 78.9 with a mean (±standard deviation) of 60.2 (±8.7). Dairy cows were on average (±standard deviation) 110.9d in milk (±79.3) with a mean (±standard deviation) milk yield of 35.2kg/d (±9.1). The RT was affected by THI, milk yield, days in milk, and WI. Up to a THI threshold of 65, RT remained constant at 39.2°C. Above this threshold, RT increased to 39.3°C and further to 39.4°C when THI ≥70. The correlation between THI ≥70 and RT was 0.22, whereas the coefficient ranged between r=-0.08 to +0.06 when THI <70. With increasing milk yield, RT decreased slightly from 39.3°C (<30kg/d) to 39.2°C (≥40kg/d). For daily milk yields of ≥40kg, the median RT and daily milk yield were correlated at r=-0.18. The RT was greater when dairy cows yielded ≥30kg/d and THI ≥70 (39.5°C) compared with milk yields <30kg and THI <70 (39.3°C). The WI, which averaged (±standard deviation) 11.5 l (±5.7) per drinking bout, caused a mean decrease in RT of 3.2°C and was affected by the amount of WI (r=0.60). After WI, it took up to 2h until RT reached the initial level before drinking. In conclusion, RT increased when the THI threshold of 65 was exceeded. A further increase was noted when THI ≥70. Nevertheless, the effects of WI and milk yield have to be considered carefully when RT is used to detect hyperthermia in dairy cattle.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...

